Security Function Ver. 1.02 Mar. 2016
8. Service Mode functions
25
• When “ON” is set for Enhanced
S
ecurity Mode, the machine is set into an access
lock state if a wrong CE password is entered a predetermined number of times.
Then, access to the
S
ervice Mode cannot be made until the access lock state is
released.
For the procedure to release the access lock state, see P.10.
5.
Type the password to be newly used from the keyboard shown on the display and touch
[END].
NOTE
• When [Password Rules] is set to "Enable" for [Administrator
S
ettings]
→
[
S
ecurity
S
ettings]
→
[
S
ecurity Details], the machine does not accept any new password
that contains only the same character or that is the same as the previous pass-
word.
Also, when the number of password characters is lower than the minimum number
of characters (initial value: 12 characters) as set out under [
S
et Minimum Pass-
word Length] in the [Password Rules], a new password will not be able to be set.
• The CE password should be set at a value which is not the initial value and which
is difficult to guess.
• Quitting the
S
ervice Mode after the new password has been set will validate the
setting of the new password.
A7AH