10
Index
1. General safety rules
2. Appliance description
3. Technical data
4. Installation instructions
5. Instructions for use
6. Maintenance
7. Troubleshooting
1. General safety rules
• READ THE INSTRUCTIONS
GIVEN IN THIS HANDBOOK
BEFORE USING THE APPLI
-
ANCE.
• The electrical system to which
the appliance is connected must
comply with current legislation.
It is advisable to install a differ
-
ential magneto-thermal switch
ahead of the power outlet.
• Always unplug the appliance
before performing any mainte-
nance operations.
• Before using the appliance,
check the power cable. It must
not be bent, taut, crushed or
damaged in any way.
• The power cable must be re-
placed by qualified personnel
only. Use a H07RN type cable
only with plug protected against
splashes of water.
• Do not touch the exhaust gas
outfeed. Danger of burns!
• The appliance must be installed
for industrial use only.
2. Description of the appliance
• Mobile, oil-fired hot air generator
with closed combustion cham-
ber and connection duct to a
stack for fume exhaust.
3. Technical data
GB
Type
KAI 20
KAI 35
KAI 65
Heating power (kW)
25
40
75
Air delivery (m
3
/h)
1100
2050
3000
Oil consumption (kg/h)
2,12
3,39
6,35
Sound pressure (db(A))
72
70
71
Voltage (V)
230/50 Hz
230/50 Hz
230/50 Hz
Motor power (W)
450
540
670
Current intake (A)
1,5
2,4
2,7
Weight (kg)
59
75
105
Length (mm)
1160
1250
1560
Width (mm)
580
580
660
Height (mm)
950
1050
1190
Stack diameter (mm)
140
140
140
Tank capacity (l)
38
80
80