472405/A
117
K-Sync interface to Remote Control Unit
A dedicated junction box has been designed to provide remote on/off switches with light
indication and interface to a remote synchronizing system. The junction box contains a
terminal block and four switches with lamps mounted in the front.
The Remote Control Unit is called K-Rem. It is prepared for remote control and interface
to an external synchronization system up to four KONGSBERG echo sounders.
A
Connections in the Remote Control Unit (K-Rem)
B
Connections on the K-Sync IO Module
The pin configuration on the
K-Sync IO Module follows:
Pin no.
Signal
Description
1
TRIG OUT
Trigger out – Signal to external device enabling it to transmit
2
GROUND
Mandatory – connected to pin 5 inside the module
3
RTT
Ready to transmit – Input from external device when it is ready for the next
trigger pulse
4
TRIG IN
Trigger in – Input from external device, active while the device is transmitting
5
GROUND
Mandatory – connected to pin 2 inside the module
6
Not used
Each IO Module in the K-Sync Synchronizing Unit provides six connectors and a
configuration board for physical adjustments of the communication parameters.
Connectors 1 through 6 as indicated by the arrows.
Note that each of the two connector elements can be pulled out of the IO Module for
easy access.
Configuration board
Summary of Contents for EM 2040 MKII
Page 8: ...8 472405 A KONGSBERG EM 2040 MKII...
Page 92: ...92 472405 A Related topics List of cables page 101 KONGSBERG EM 2040 MKII Installation Manual...
Page 177: ...472405 A 177 338208 RX transducer outline dimensions 0 7 degrees Drawing file...
Page 179: ...472405 A 179 337805 TX transducer outline dimensions 0 4 degrees Drawing file...
Page 181: ...472405 A 181 355913 Transducer mounting plate 0 4 x 0 7 degrees Drawing file...
Page 182: ...182 472405 A 359252 Baffle plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Page 183: ...472405 A 183 385422 Processing Unit dimensions Drawing file...
Page 185: ...472405 A 185 464618 HWS dimensions MC330 Rack model Drawing file...
Page 187: ...472405 A 187 370275 Remote Control Unit K REM dimensions Drawing file...
Page 247: ......
Page 248: ...2021 Kongsberg Maritime...