Operation
374876/B
17
Transponder configuration (on-deck)
Establish connection with TP
1
Select TTC Menu.
2
Connect the Serial line cable to the upper left connector
(
A)
on cPAP (Figure 4 cPAP Front panel
on page
9) and
the other connector to the bottom of the transponder (
S
).
3
Select TRANSPONDER CONFIGURATION tab.
4
The cPAP will automatically update TP information when
connected.
5
The cPAP is ready for configuration when GREEN line is
visible.
- If the line is red and no contact is made with the TP
→ check all cables and try again.
New configuration
1
Press buttons on the right hand side of the screen to
change TP info.
2
Press DOWNLOAD NEW CONFIGURATION to update
transponder.
3
New transponder info will appear on left hand side of
screen.
- If DOWNLOAD NEW CONFIGURATION is
unsuccessful a red box will appear on right hand side
with message 'Download config failed' → check all
cables and try again.
Figure 10 Transponder test and configuration
T
: Test Transducer
connected to
communication in air.
S
: Serial line connection