The interface between APOS Survey and onboard APOS is normally a high speed serial
line with a galvanic isolated connection.
APOS Survey is delivered with a MOXA Ethernet to 4 port serial unit for this purpose.
In order to transfer data between the two systems, a small program called ASI (APOS
Survey Interface) has to be installed on the existing vessels APOS system. This program
must be kept running at all times in order to keep the communication between the two
systems. The ASI program will transfer settings from the onboard vessel system to the
APOS Survey, but not the other way. In addition it will enable the APOS Survey to
communicate with the on board transceivers.
Hardware installation
Preparation
If the system is used for rental purposes it shall be reset before next use. This is done by
re-installing the software from image disk.
Cabling
No.
Cable type
Length
P/N
1
Ethernet cable
5 m
(Note 1)
719-077276