UAB AMALVA we reserve the right to make changes without prior notice
25
TECHNICAL INFORMATION
Specifications
REGO 200VE(W)
Dimensions
EC VE/VW
Nominal air flow
m
3
/h
300
Unit weight
kg
42
Capacity
kW
0,8 / 1,2
Input power
W
2×70
Supply voltage
V / Hz
~230 / 50 /1 phase
Maximal operating current
A
5,1 / 0,76
Ductwork connection
mm
125
Thermal efficiency of rotary heat exchanger up to
%
80
Energy recovery of rotary heat exchanger up to
kW
2,27
Filters
Supply air
Exhaust air
Dimensions
Filter class
F7
F7
Type
Panel
Panel
Dimensions b×h×l
285×130×46
285×130×46
mm
REGO 200VE(W*)-B-EC Performance
Static pressure, Pa
Air volume, m
3
/h
Fan power
, W
*
Correction factor for REGO 200VW – 25 Pa.