REMARK
If heavy-duty operation is performed for more than 30 minutes
with the fuel control dial between Low idle (MIN) position and
High idle (MAX) position, soot is accumulated much and action
level monitor “L03” may be displayed. However, this does not
indicate abnormality.
After performing manual stationary regeneration, turn the fuel
control dial to a point above the midpoint between Low idle
(MIN) position and High idle (MAX) position to continue the op-
eration.
When the degree of emergency is low
• If KDPF soot accumulation caution lamp (2) lights up in
yellow (action level (3): L01), screen (A) is displayed first.
• The action level goes out 2 seconds after and the screen
changes to standard screen (B).
• If the lock lever is set to LOCK position or all the work
equipment control levers are set in NEUTRAL, the screen
changes to aftertreatment devices regeneration screen (C)
after 3 seconds only the first time. If the manual stationary
regeneration is not performed, the screen returns to stand-
ard screen (B) after 30 seconds.
Then, if the accumulated soot does not decrease, the af-
tertreatment devices regeneration screen (C) is displayed
for 30 seconds every 2 hours.
• If KDPF soot accumulation caution lamp (2) lights up in
yellow, stop the machine in a safe place after finishing the
work and perform the manual stationary regeneration.
EXPLANATION OF COMPONENTS
OPERATION
3-118
Summary of Contents for PC490-11
Page 2: ......
Page 25: ...LOCATION OF SAFETY LABELS a b c d e f g h KS000848 T T SAFETY SAFETY LABELS 2 5...
Page 72: ......
Page 340: ......
Page 421: ...SPECIFICATIONS 5 1...
Page 425: ...6 7m Boom PC490 11 SPECIFICATIONS SPECIFICATIONS 5 5...
Page 426: ...6 7m Boom PC490LC 11 SPECIFICATIONS SPECIFICATIONS 5 6...
Page 428: ...7 1m Boom PC490 11 SPECIFICATIONS SPECIFICATIONS 5 8...
Page 429: ...7 1m Boom PC490LC 11 SPECIFICATIONS SPECIFICATIONS 5 9...
Page 430: ......
Page 474: ......
Page 475: ...REPLACEMENT PARTS 7 1...
Page 491: ......