130
PERIODICAL CHANGE OF THE COMPONENTS THAT ARE CONNECTED WITH SAFETY
4.6.1 CRITICAL PARTS FOR SAFETY
FUEL SUPPLY SYSTEM
•
For the serial numbers and the quantity of the components that periodically need changing, consult the spare
parts catalogue section regarding the components connected with safety and the components that must be pe-
riodically changed.
•
When changing pipes, always change the O-rings, the gaskets and analogous components.
No
Components related to safety that periodically need changing
Qty
Change interval
1
Fuel pipe (Fuel tank – precleaner)
1
Every 2 years or 4000
hours, whichever oc-
curs first
2
Fuel pipe (Precleaner - fuel pump)
1
3
Fuel pipe (Fuel pump - fuel filter)
1
4
Fuel pipe (Fuel filter – injection pump)
1
5
Fuel pipe (Fuel filter - fuel tank)
1
6
Fuel recovery pipe (Fuel filter - Injection pump)
1
7
Fuel recovery pipe (Between the injectors)
2
8
Fuel recovery pipe (Injector - Injection pump)
1
9
Fuel recovery plug
1
RWA09130
5
3
4
2
1
6
9
7
8
Summary of Contents for PC20R-8
Page 2: ......
Page 12: ...10...
Page 20: ...18...
Page 21: ...SAFETY AND ACCIDENT PREVENTION...
Page 23: ...SAFETY NOISE AND VIBRATION PLATES 21 MACHINE WITH CANOPY RWA00010 RWA00030 RWA00020 RYA11890...
Page 54: ...52...
Page 55: ...THE MACHINE AND ITS OPERATIONS...
Page 118: ...116...
Page 119: ...MAINTENANCE...
Page 172: ...170...
Page 173: ...TECHNICAL SPECIFICATIONS...
Page 182: ...180...
Page 183: ...AUTHORISED OPTIONAL EQUIPMENT...