KC3 PV Charge Controller Instruction Manual
9
7) No.7 is to set the voltage when lighting control is on or off.
This setting is for KC3 to check grade of the sunlight under Lighting Mode.
8) No.8 is to set the delay time when solar modules reach the opening voltage under Lighting
Mode.
Note:
The data won’t be saved if the set one exceeds to require one, KC3 will still run according
to the previous setting
Diagram 6 First roll (page) shown on LCD
Diagram 7 Second roll (page) shown on LCD
■
Buttons Operations
LCD Light turns on when Buttons Operations, turns off 10 seconds after Buttons Operations.
LCD Light keeps on under setting status, turns off 5 seconds after back to normal status.
4 buttons on KC3: “setting button” “next” “up/increase” “down/reduce”
●
“setting button”
Under normal status (when LCD shows the working status), press and hold 5 seconds setting
button to enter the setting status.
Under setting status, cursor flashes on where data needs adjusted, the position of cursor is
moveable. Press “next” to change the cursor position. Press “up/increase” or “down/reduce” to
adjust the data where cursor located.
Press setting button under setting status to save the changed data, the LCD turns over to next
page. Under setting status, press and hold 5 or 10 seconds of setting button, setting status
done and turn back to normal status.
Under normal status, press setting button, LCD turns over to next page to show more working
1.TIME HH:MM:SS
2.Ibat(max)
.
.
.
XX.X
3.Vbat(max)
.
.
.
XX.X
4.Vbat(min)
.
.
..
XX.X
5.LD_M
..
...
..
.
PV
6.LD_T
.
XX:XX
.
XX:XX
7.PV_ON_V
..
..
X.X
8.PV_DLY_T
.
..
.
XX
SET
SET