KC3 PV Charge Controller Instruction Manual
7
Diagram 4 Second roll (page) shown on LCD
Diagram 5 Third roll (page) shown on LCD
■
Setting
Under setting status, output control won’t re-detect if working mode not changed.
Output will re-detect if working mode is changed.
4 data for setting: Time, Lighting Control, mode and data of loads.
Table 2. Data setting
No. Display
Meaning
Unit
Format
Factory
setting
Remark
1 TIME Current
Time
HH:MM:SS
00:00:0
0
hour:minute:second
For time checking
2 Ibat(max)
Maximum Battery
charging current
A XX
.
X
40.0
Set within 5.0A-40.0A
3 Vbat(max)
Allowed Maximum
Battery Charging
Current under 25
℃
V XX
.
X
14.4 /
28.8
Set within 14.4V-15.0V
4 Vbat(min)
Battery over
Discharging Voltage
under 25
℃
V XX
.
X
10.8 /
21.6
Set within 10.5V-11.0V
(automatically doubled in
24V system)
5 LD_M
Working Mode of
Loads.
PV
4
Modes
6 LD_T
On & off Time of
loads
HH:MM
HH:MM
07:50
17:10
On Time setting
available under timing
mode
off Time setting available
5.Vbat
.
..
...
..
XX.X
6.Iw
.
...
..
...
.
XX.X
7.Pw
...
..
...
.
XXX
8.Tbat
.
.
..
...
.
XXX
9.TIME XX:XX:XX