Vers. 062721
48
FATc: the calibration value of the transducer, also available in the calibration certificate
of the tool). Modifying this value requires a Service Passcode. Contact Kolver to
schedule a factory re-calibration or to obtain the service passcode and calibration
instructions to perform the re-calibration in-house.
(2)
REVERSE BUTTON
Defines the behavior of the reverse button on the KDS screwdriver and on the remote
reverse command. The two modes available are BUTTON and SWITCH.
BUTTON mode: the screwdriver will run in reverse only while pressing the reverse
button on the KDS screwdriver or while sending the remote reverse command.
SWITCH mode: pressing and releasing the reverse button on the KDS screwdriver or
sending the remote reverse command will activate the reverse mode on the KDS
screwdriver. Press the lever on the KDS screwdriver or send the remote start command
while in this mode to make the screwdriver run in reverse. The LEDs on the screwdriver
will flash while this mode is active and the screwdriver is not turning.
(3)
CMD OK-ESC-RESET
Changes the source for the commands “OK”, “ESC” (see “press OK” and “press ESC”
settings on the PROGRAMS > OTHER menu), and “RESET” (see (4) below).
Choose “INT” (internal) to only allow these inputs from the touch screen display.
Choose “EXT” (external) to only allow these inputs to be received via external signals on
the CN3 connector.
Choose “INT+EXT” to allow the OK/ESC/RESET commands from both the touch screen
display and the external signals on CN3.
(4)
RESET TYPE
Defines the behavior of the reset (“RST”) button and external reset signal.
OFF mode: disables the reset button and external signal.
PRG: resets the screws made counter of the current program to zero.
SCREW: decreases the screws made counter of the current program by one.
SEQ: resets the current sequence back to the first program and resets the screws made
counter to zero. This option is will only appear if SEQUENCE mode is active
(SEQUENCE toggle on the Sequence Settings menu).
(5)
REMOTE PR
Toggle this to enable program selection via external input signals on the CN3 connector.
Refer to the remote I/O chapter of this manual for more information.
(6)
REMOTE SEQ
Toggle this to enable sequence selection via external input signals on the CN3
connector. Refer to the remote I/O chapter of this manual for more information.
(7)
BARCODE MODE
Choose between one of four barcode modes:
OFF: disables/ignores barcode scans and settings
ON S.N. (“on Serial Number”): on the main screen, the scan barcode screen will appear.
Scanning a barcode will temporarily associate it with the current program. The barcode
will be printed in the corresponding results string on the serial port and on the
corresponding Modbus field (see serial print and remote I/O chapters on this manual).
Summary of Contents for K-DUCER
Page 1: ...KDU1 KDU1A Torque range 0 1 70 Nm OPERATOR MANUAL...
Page 22: ...Vers 062721 22 Main Screen Program Mode navigation tree...
Page 25: ...Vers 062721 25 Main Screen Sequence Mode navigation tree...
Page 32: ...Vers 062721 32 PROGRAMS menu tree...
Page 33: ...Vers 062721 33...
Page 34: ...Vers 062721 34...
Page 44: ...Vers 062721 44 SEQUENCE SETTINGS menu tree...
Page 53: ...Vers 062721 53 USB menu tree...
Page 59: ...Vers 062721 59...