Vers. 062721
37
-
Lever: the angle measurement starts as soon as the screwdriver level is pressed
-
Ext In: the angle measurement starts after the IN-ANG external I/O signal is received
(13)
Exit/Save key
Tap to return to the previous menu and save or discard any changes made.
RAMP & TIME menu
(1)
Program number
Indicates the program that is currently being edited. You can select a different program
to edit from the previous screen.
(2)
RAMP
The ramp function makes the screwdriver gradually accelerate to the target SPEED
Enter a time between 0.3 and 3 seconds to set the duration of the ramp phase.
If OFF, the screwdriver starts immediately turning at the target SPEED when the lever is
pressed (or when the screwdriver starts through remote control).
If ON, the screwdriver speed will ramp up to the target SPEED in the time set.
If you wish to display an error when the screwdriver reaches target torque or angle
during the ramp phase, use the (4) MIN TIME function with a timer value equal to the
RAMP timer.
(3)
RUN TIME
The RUN TIME function makes the screwdriver stop after the set timer, irrespective of
the torque or angle reached.
If ON, the screwdriver will stop after the set amount of time or when the torque or angle
targets are reached, whichever event happens first. If the run time is reached before the
target torque or angle, then the torque and angle reached at the time the screwdriver
Summary of Contents for K-DUCER
Page 1: ...KDU1 KDU1A Torque range 0 1 70 Nm OPERATOR MANUAL...
Page 22: ...Vers 062721 22 Main Screen Program Mode navigation tree...
Page 25: ...Vers 062721 25 Main Screen Sequence Mode navigation tree...
Page 32: ...Vers 062721 32 PROGRAMS menu tree...
Page 33: ...Vers 062721 33...
Page 34: ...Vers 062721 34...
Page 44: ...Vers 062721 44 SEQUENCE SETTINGS menu tree...
Page 53: ...Vers 062721 53 USB menu tree...
Page 59: ...Vers 062721 59...