Vers. 062721
24
(9)
Torque measurement unit
You can select a different unit from the GENERAL SETTINGS menu.
(10)
Status bar
Shows the last screw result or error messages (ready, screw OK, screw NOK, errors).
(11)
Torque target
Shows the target torque when in torque control mode, or the min/max torque bounds
when in angle control mode or timed rundown mode, for the current program.
(12)
Torque value
Measured torque value applied to the last screw.
(13)
Current and next program numbers in sequence
Shows the current program loaded in the sequence in larger font, and the following
program numbers in the sequence.
(14)
Program count
Counter: programs successfully completed / number of programs in current sequence