Owner’s Manual

6SS12BEA2ACA0 / 6SS24BGA2ACA0

Operation

CONTROL PANEL

1.  POWER BUTTON: Activates unit when POWER BUTTON is pressed. (Fan starts on low speed). 

 

If power button is pressed during operation, unit stops.

2.  BLOWER BUTTON: Changes fan speed from (Low) to (High) when pressed.

3.  SPOT/COOL BUTTON: Activates compressor and begins producing cool air 2 minutes after button is pressed. 

Regulates temperature based on discharge air temperature.

4.  ROOM/COOL BUTTON: Activates compressor and produces cool air 2 minutes after button is pressed. 

Regulates temperature based on Return/room air temperature.

5.  SET TEMP BUTTONS: Change target temperature/data value by +/- 1. Change data value by +/- 10 by holding.

 

Press the SET TEMP BUTTONS to set temperature.

 

Upper button is to heighten temperature and Lower button is to lower temperture.

6.  ALARM: Alarm indicator lights (blinks) and indicates abnormal system operation. If Alarm occurs, compressor 

stops.System operation stops when ALARM light is activated (blinks) longer than 3 minutes.

7.  CURRENT TEMP: Displays current room temperature in display in Farenheit. (In Room Cool Mode only). 

SPOT/COOL Mode – Displays outlet (cool air) temperature during normal operations. ALARM codes blink 

and are displayed when abnormal operation occurs.

8.  TARGET TEMP displays the unit set temperature for ROOMCOOL mode only.

TIMER: Enter to Timer setting mode if you press SPOT/COOL button and ROOM/COOL button together for 

3 seconds. Press UP/DOWN button to set the timer until it shows the figure you want to set. After 3 

seconds, the figure will be memorized and compressor will stop after the time set.

Figure 7

5

6SS12BEA2ACA0 / 6SS24BGA2ACA0

Owner’s Manual

5

WSC-4000 / WSC-6000

Owner’s manual

Operation

CONTROL PANEL

1. POWER BUTTON: Activates unit when POWER BUTTON is pressed. (Fan starts on low speed).

    If power button is  pressed during operation, unit stops.

2. BLOWER BUTTON: Changes fan speed from (Low) to (High) when pressed.

3. SPOT/COOL BUTTON: Activates compressor and begins producing cool air 2 minutes after button is pressed.

    Regulates temperature based on outlet cool air temperature.

4. ROOM/COOL BUTTON: Activates compressor and produces cool air 2 minutes after button is pressed.

    Regulates temperature based on inlet ambient air temperature.

5. SET TEMP BUTTONS: Change target temperature/data value by +/- 1. Change data value by +/- 10 by

    pressing continually.

    Press the SET TEMP BUTTONS to set temperature.

    Upper button is to heighten temperature and Lower button is to lower temperture.

6. ALARM: Alarm indicator lights (blinks) and indicates abnormal system operation. If Alarm occurs, compressor

    stops.System operation stops when ALARM light is activated (blinks) longer than 3 minutes.

7. CURRENT TEMP: Displays current room temperature in display in Celsius. (In Room Cool Mode only).

    SPOT/COOL Mode – Displays outlet (cool air) temperature during normal operations. ALARM codes blink and

    are displayed when abnormal operation occurs.

8. TARGET TEMP displays the unit set temperature for ROOMCOOL mode only.

TIMER: Enter to Timer setting mode if you press SPOT/COOL button and ROOM/COOL button together for

              3 seconds. Press UP/DOWN button to set the timer until it shows the figure you want to set. After 3

              seconds, the figure will be memorized and compressor will stop after the time set.

Figure 7

1

2

3

4

5

6

8

7

4

WSC-4000 / WSC-6000

Owner’s manual

Unlock the casters and push the unit using the side handles to a flat, level surface and set the caster brakes to

the locked position.

Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or dirt are present, wipe off with

a clean, dry cloth.

Check the power cord, plug and prongs for damage or excess play.

If any damage or excess play is found, contact a qualified repair technician or a qualified electrician to perform

replacement or repair of the power cord, plug or prongs.

NOTE

: Make sure the AC outlet is free of dirt, dust, oil, water, or any other foreign material.

Do not use the unit in explosive environments or in areas where flammable

gas leakage may occur.

If the power cord or plug is damaged, repair should only be performed by

qualified electrical personnel.

Do not connect / disconnect the power cord or attempt to operate buttons with

wet hands. This could result in electrical shock.

Do not install the unit on uneven or sloping surface. The unit may roll or topple

over even if the casters are set to the locked position.

Do not use the Indoor unit in areas where it will be exposed to rain or water.

Do not use the unit in a corrosive atmosphere.

Do not use the unit above 18°C(64.4°F) ~ 52°C(125.6°F).

Installation

WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION

MOVING THE UNIT

PLUGGING IN THE UNIT

HOW TO CONNECT THE LINES BETWEEN INDOOR UNIT AND OUTDOOR UNIT

Assembly(Continued)

Connect between the same numbers.

1. Power cord : To supply power to the outdoor unit.

2. Drain hose : To drain condensate to the outside.

3. Cooling water line and coupling (Cool water)

4. Cooling water line and coupling (Hot water)

NOTE

: Cooling water lines are 5 meters or

             10 meters in length. please check with

             the shop you bought this unit. 

1 2

3

4

Figure 5

Figure 6

IN

OUT

INDOOR UNIT

OUTDOOR UNIT

1

3

4

2

IN OUT

Summary of Contents for 6SS12BEA2ACA0

Page 1: ...ot cool or room cool functions The spot cool is designed to deliver very cold air for a continuous amount of time The room cool feature is designed to work with a set point based on room air The unit...

Page 2: ...electrician and all local electrical codes to ensure proper setup Any extension cord used with this device must be rated for a minimum of 15A 18 DO NOT unplug the unit by pulling on the electrical cor...

Page 3: ...haust part discharge of hot air Electrical part Electrical control box Side handle Cooling water air purge control CONDENSER Fresh air inlet for cooling nonfreezing cooling water Caster Figure 2 Figur...

Page 4: ...ther foreign material Do not use the unit in explosive environments or in areas where flammable gas leakage may occur If the power cord or plug is damaged repair should only be performed by qualified...

Page 5: ...be memorized and compressor will stop after the time set Figure 7 5 6SS12BEA2ACA0 6SS24BGA2ACA0 Owner s Manual 5 WSC 4000 WSC 6000 Owner s manual Operation CONTROL PANEL 1 POWER BUTTON Activates unit...

Page 6: ...eration If the fault persists for more than 3 minutes the evaporator fan also stops The fault must be rectified before the unit can resume normal operation Customer Please read and keep this manual fo...

Page 7: ...air filter b Ambient temperature is too high c Cooling pump is not operate normally d Power is not supplied to outdoor unit TH1 outlet temperature sersor has a loose or broken connection TH2 inlet tem...

Page 8: ...8 Owner s Manual 6SS12BEA2ACA0 6SS24BGA2ACA0 Wiring Diagram 8 6SS12BEA2ACA0 6SS24BGA2ACA0 Owner s Manual Wiring Diagram Figure 10 Circuit Wiring Diagram Figure 10 Circuit Wiring Diagram...

Page 9: ...ool 1 Only BlOWER light on ROOM COOL and SPOT COOL light off 2 Compressor will start in 2 minutes after unit is restarting 3 The ambient temperature may be too high 1 Press ROOM COOL button or SPOT CO...

Page 10: ...our dealer for assistance If you cannot reach your dealer or if they cannot resolve the problem call Koldwave Portable Air Conditioner Technical Support at 413 564 5530 Please have the following infor...

Page 11: ...11 Owner s Manual 6SS12BEA2ACA0 6SS24BGA2ACA0...

Page 12: ...2 Owner s Manual 6SS12BEA2ACA0 6SS24BGA2ACA0 260 North Elm St Westfield MA 01085 Phone 413 564 5520 Fax 413 564 5530 www koldwave com For Koldwave warranty please visit http koldwave com warranty aspx...

Reviews: