background image

Physical 

Assessment 

Trainer

Heart Auscultation / Percussion / Palpation

LM-084

Instruction Manual

Thank you for purchasing the LM-084 Physical Assessment Trainer.
Please read this instruction manual carefully to ensure correct use of the product,
and store it in a safe place for easy access. 

KOKEN CO., LTD. 

1-4-14 Koraku, Bunkyo-ku, Tokyo 112-0004 JAPAN 
URL:http://www.kokenmpc.co.jp 
E-mail:[email protected] 

© 2008-2020   KOKEN CO., LTD.   C-1-960-1-02-03

Summary of Contents for LM-084

Page 1: ...e LM 084 Physical Assessment Trainer Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Koraku Bunkyo k...

Page 2: ...eton may be deformed 3 Please store the model in the attached case while it is not used 4 Please wipe stains of the model with wet gauze etc Using water or a neutral detergent diluting with water Plea...

Page 3: ...2 Table of Contents 1 Outline Characteristics 2 Composition and Name 3 How to Handle Model Disposition of speaker Case Data 4 How to Perform Percussion 5 Physical Assessment 6 Others 7 Specification...

Page 4: ...n Percussion of thorax By injecting air into simulation lungs you can adjust the air and set the normality abnormality of each simulation lung 4 Auscultation Auscultation of heart and breathing Breath...

Page 5: ...lt for xing model base 1 Pump for in ating simulation lungs 1 Heart and breathing sound source 1 Cord for connecting model and heart breathing sound source 1 Power supply cord for heart breathing soun...

Page 6: ...s Right Left Thyroid gland Lymph node Main body sponge Speaker cable Sponge pant for lumbus Silicone part for lumbus Connector for heart breathing sound source In ating connector for lungs In ation co...

Page 7: ...ctor of the cord for connecting the model with the heart and breathing sound source into the hole on the right back side of main body After connecting the female connector with the connector inside th...

Page 8: ...de speaker output One of the sounds chosen from 4 kinds of heart sound A P T M and 3 kinds of breathing sound left and right lung respiratory tract can be outputted by connecting outside speaker Outsi...

Page 9: ...Flip over the heart and breathing sound source Remove the cap on the lower left corner The AC switching lever can be seen through the hole uncovered when the cap is removed By using long nose pliers...

Page 10: ...eathing sound source fix with the screw Connect the plug cord with the heart and breathing sound source Connect the plug code with the socket and turn on the power switch 3 4 How to Operate Heart and...

Page 11: ...eathing sound for the right lung and then press the E key refer page 11 of this manual The liquid crystal display shows H NO HR L B R B ST and then a case sound you set is outputted Each case sound vo...

Page 12: ...sition of speaker Heart Sounds HEART SOUND A HEART SOUND P HEART SOUND T HEART SOUND M Breathing Sounds BREATHING SOUND LL BREATHING SOUND T BREATHING SOUND RL BREATHING SOUND RL and LL position is ba...

Page 13: ...ubaortic stenosis Atria septal defect Ventricular septal Pulmonic stenosis Pulmonic steno regurgitation Patent ductus arteriosus Normal vesicular sounds Discontinuous sounds ne crackles Discontinuous...

Page 14: ...ound Open empty lack of air in simulation lung Left Normal breathing sound Inflated filled with air in simulation lung Both left and right normal sound After inflating air into the one side simulation...

Page 15: ...connector for inflating which is on the side of lung you set for normal Grasp the rubber ball of the pump for inflating simulation lungs and then put air into the simulation lungs to be inflated aroun...

Page 16: ...fter inflating the left lung For normal breathing sound For Abnormal Connect the pump for inflating the simulation lungs with the connector for injecting air into the lung you choose as abnormal Turni...

Page 17: ...on of Thyroid Gland Inject air with the syringe from the tip of the tube coming out of the lower part of the model Before injection the air after injection the air Please take off the syringe from tub...

Page 18: ...n the base can be disconnected using attached hexagonal wrench 7 Specification Lymph node on upper Darcie Height Width Length Weight Torso Main Body Model Base 54cm cm 38 cm 21cm Approx Approx 7 kg 1...