The voltage of this unit can be switched between 110 V and 220 V to match the voltage 

of the power source being used. (Default setting: 110V)

○ How to switch the AC voltage
* Always remove the power cord from the unit before switching the AC voltage of the heart and
breathing sound source.
①  Flip over the heart and breathing sound source.

②  Remove the cap on the lower left corner.

③  The AC switching lever can be seen through the hole uncovered when the cap is removed. By 

using long-nose pliers and so on, switch to the voltage of the power source being used.

  (The label of 110V and 220V can be found through the hole when the cap is removed)

④  Replace the cap.

 

 

 

- 7 - 

 

本器は110 又は220 切り替え方式になっており、使用場所の電圧に設定可能です。

(初期設定 :110 )

○ 電圧切り替え方法

※心音呼吸音発生器のAC電圧を切り替える際は必ず本器から電源コードを外して行って下さい。

①心音呼吸音発生器を裏返します。

②心音呼吸音発生器の左下にあるキャップを外します。

③キャップを外した窓から 電圧切り替えレバーが見えますので、

ラジオペンチ等を用いて

使用場

所の電圧に切り替えます。

(110

、220の表示はキャップを外した窓から確認できます。)

④キャップを元に戻します。

切り替えレバーを手前(矢印方向)に引くとロック

が解除されます。

ロックが解除された状態で電圧を切り替えること

ができます。

 

 

 

キャップ

 

 

 

 

- 7 - 

 

本器は110 又は220 切り替え方式になっており、使用場所の電圧に設定可能です。

(初期設定 :110 )

○ 電圧切り替え方法

※心音呼吸音発生器のAC電圧を切り替える際は必ず本器から電源コードを外して行って下さい。

①心音呼吸音発生器を裏返します。

②心音呼吸音発生器の左下にあるキャップを外します。

③キャップを外した窓から 電圧切り替えレバーが見えますので、

ラジオペンチ等を用いて

使用場

所の電圧に切り替えます。

(110

、220の表示はキャップを外した窓から確認できます。)

④キャップを元に戻します。

切り替えレバーを手前(矢印方向)に引くとロック

が解除されます。

ロックが解除された状態で電圧を切り替えること

ができます。

 

 

 

キャップ

 

1. Point the switching lever towards you
   (in the direction of arrow) to unlock it.

2. When unlocked, switch the voltage.

1

2

Cap

Summary of Contents for LM-084

Page 1: ...e LM 084 Physical Assessment Trainer Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Koraku Bunkyo k...

Page 2: ...eton may be deformed 3 Please store the model in the attached case while it is not used 4 Please wipe stains of the model with wet gauze etc Using water or a neutral detergent diluting with water Plea...

Page 3: ...2 Table of Contents 1 Outline Characteristics 2 Composition and Name 3 How to Handle Model Disposition of speaker Case Data 4 How to Perform Percussion 5 Physical Assessment 6 Others 7 Specification...

Page 4: ...n Percussion of thorax By injecting air into simulation lungs you can adjust the air and set the normality abnormality of each simulation lung 4 Auscultation Auscultation of heart and breathing Breath...

Page 5: ...lt for xing model base 1 Pump for in ating simulation lungs 1 Heart and breathing sound source 1 Cord for connecting model and heart breathing sound source 1 Power supply cord for heart breathing soun...

Page 6: ...s Right Left Thyroid gland Lymph node Main body sponge Speaker cable Sponge pant for lumbus Silicone part for lumbus Connector for heart breathing sound source In ating connector for lungs In ation co...

Page 7: ...ctor of the cord for connecting the model with the heart and breathing sound source into the hole on the right back side of main body After connecting the female connector with the connector inside th...

Page 8: ...de speaker output One of the sounds chosen from 4 kinds of heart sound A P T M and 3 kinds of breathing sound left and right lung respiratory tract can be outputted by connecting outside speaker Outsi...

Page 9: ...Flip over the heart and breathing sound source Remove the cap on the lower left corner The AC switching lever can be seen through the hole uncovered when the cap is removed By using long nose pliers...

Page 10: ...eathing sound source fix with the screw Connect the plug cord with the heart and breathing sound source Connect the plug code with the socket and turn on the power switch 3 4 How to Operate Heart and...

Page 11: ...eathing sound for the right lung and then press the E key refer page 11 of this manual The liquid crystal display shows H NO HR L B R B ST and then a case sound you set is outputted Each case sound vo...

Page 12: ...sition of speaker Heart Sounds HEART SOUND A HEART SOUND P HEART SOUND T HEART SOUND M Breathing Sounds BREATHING SOUND LL BREATHING SOUND T BREATHING SOUND RL BREATHING SOUND RL and LL position is ba...

Page 13: ...ubaortic stenosis Atria septal defect Ventricular septal Pulmonic stenosis Pulmonic steno regurgitation Patent ductus arteriosus Normal vesicular sounds Discontinuous sounds ne crackles Discontinuous...

Page 14: ...ound Open empty lack of air in simulation lung Left Normal breathing sound Inflated filled with air in simulation lung Both left and right normal sound After inflating air into the one side simulation...

Page 15: ...connector for inflating which is on the side of lung you set for normal Grasp the rubber ball of the pump for inflating simulation lungs and then put air into the simulation lungs to be inflated aroun...

Page 16: ...fter inflating the left lung For normal breathing sound For Abnormal Connect the pump for inflating the simulation lungs with the connector for injecting air into the lung you choose as abnormal Turni...

Page 17: ...on of Thyroid Gland Inject air with the syringe from the tip of the tube coming out of the lower part of the model Before injection the air after injection the air Please take off the syringe from tub...

Page 18: ...n the base can be disconnected using attached hexagonal wrench 7 Specification Lymph node on upper Darcie Height Width Length Weight Torso Main Body Model Base 54cm cm 38 cm 21cm Approx Approx 7 kg 1...

Reviews: