IMPORTANT INFORMATION

INSTRUCTIONS PERTAINING TO A RISK OF FIRE,

ELECTRICAL SHOCK, OR INJURY TO PERSONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

12V

30mA

(RCD)

WARNING:

WARNING:

WARNING:

WARNING:

WARNING:

WARNING:

WARNING:

The supply cord cannot be replaced.

If the cord is damaged the appliance should be
scrapped.

The appliance is not to be used by

persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction.

Children being supervised not to

play with the appliance.

Parts containing live parts, except

parts supplied with safety extra-low voltage not
exceeding 12V, must be inaccessible to a person
in the bath.

Earthed appliances must be

permanently connected to fixed wiring.

Parts incorporating electrical

components, except remote control devices,
must be located or fixed so that they cannot fall
into the bath.

The appliance should be supplied

through a residual current device (RCD) with a
rated tripping current not exceeding 30 mA.

QB 2585-2007

WARNING: Risk of personal injury.

WARNING: The use of alcohol, drugs, or
medication can greatly increase the risk of
fatal hyperthermia.

To avoid

injury, exercise care when entering or exiting the
whirlpool bath.

Prolonged immersion in hot

water may induce hyperthermia.

NOTE:

Please do not use the bath in case of

outage. In this case, the electronic drain
automatically opens and the bath can not be
filled with water.

This product complies with QB 2585-2007.

Summary of Contents for WHIRLPOOL

Page 1: ...1 WHIRLPOOL BATH OWNER S MANUAL 1283904 T01 B SHANGHAI KOHLER LTD NO 368 MIN LE ROAD FENG XIAN DISTRICT SHANGHAI CHINA POST CODE 201419 368 201419 Copyright Kohler China Investment Co Ltd 2016 2016 ...

Page 2: ...ions We re proud of our whirlpool bath here at Kohler and we know you will be too Please take a few minutes to study this Homeowners Guide before you use your whirlpool bath Pay special attention to the Care and Cleaning instructions in this manual All information in this manual is based upon the latest product information available at the time of publication At Kohler we constantly strive to impr...

Page 3: ...with safety extra low voltage not exceeding 12V must be inaccessible to a person in the bath Earthed appliances must be permanently connected to fixed wiring Parts incorporating electrical components except remote control devices must be located or fixed so that they cannot fall into the bath The appliance should be supplied through a residual current device RCD with a rated tripping current not e...

Page 4: ...ould be restored If the RCD fails to operate in this manner the RCD is defective If the RCD interrupts power to the bath without the test button being pressed a ground current is flowing indicating the possibility of an electric shock Do not use this bath Disconnect the bath and have the problem corrected by a qualified service representative before using Use this whirlpool bath only for its inten...

Page 5: ...th is empty Before taking bath please make sure of water temperature with hands When massage pump is on massage strength is displayed Electronic Drain Start the drain by pushing the button once drain animation is displayed Push again to stop it When pushing this button a slight sound can be heard from the drain at the bottom of the bath Power On Off Push the button to start system and enter standb...

Page 6: ...lectronic drain on off button on the user keypad to close the drain Fill the bath Massage pump can only be started when water level is above 300mm Observe water temperature displayed on the keypad for comfort and safety make sure of water temperature with hand Carefully enter the bath basin Press pump on off and massage strength to start massage If desired adjust massage strength by pressing OPERA...

Page 7: ...erflow level the electronic drain automatically closes Sound alarm stops Refer to roughing in for overflow level When the bath reaches overflow level water level may rise quickly if you enter the bath which may trigger the compelling drain function Compelling drain function will discharge lots of water so it is not recommended to use the bath when it reaches overflow level 7 OPERATION INSTRUCTIONS...

Page 8: ...ly drains and pipe cleaning is finished In case the purge button is pressed by mistake when taking a bath please press it again to stop this function and then turn off electronic drain Note POWER OFF STATUS The electronic drain automatically starts under power off status Please do not use the bath in case of outage In this case the electronic drain automatically opens and the bath can not be fille...

Page 9: ... bath surface Wipe out your acrylic bath with a soft cloth after each use Avoid detergents disinfectants or cleaning products in aerosol cans To restore dull or scratched units Apply white automotive polishing compound with a clean rag Rub scratches and dull areas vigorously Wipe off residue Follow with a coat of white automotive paste wax Do not wax areas where you walk or stand B Cleaning Your U...

Page 10: ...CONT Turn the rod 90 Pull the rod outwards to pull out the nozzle Turn the rod 90 to pull it out of the nozzle Keep the rod for future use Insert the new nozzle into the flange and press tight The replacement process is finished 1283904 T01 B ...

Page 11: ...ut can not adjust massage strength A Controller trips A User keypad cable loose or damaged B User keypad does not work B Replace user keypad A User keypad cable loose or damaged B User keypad does not work C Controller dose not work A Check wire connections If necessary replace user keypad D Electronic adjustment valve does not work 6 Pipe cleaning does not work 7 Cannot operate or stop electronic...

Page 12: ...A User keypad cable trips B User keypad trips A Check wire connections or replace user keypad B Replace user keypad 11 Abnormity shown of water emperature 12 The bath fails to drain water A Temperature sensor of electronic drain mechanism does not work A Drain pipe on is higher than bath bottom A Replace electronic drain mechanism A Keep drain pipe close to the ground to make it lower than bath bo...

Page 13: ...nction of air switch A Replace pump B Reconnect or replace air tube C Replace air switch 2 Pump stops automatically A RCD trips A Correct RCD trips A Replace air control valve 3 Pump operates but can not adjust massage strength A Malfunction of air control valve Troubleshooting The Bath System With Air Switch Control 1 A B C A B C 3 2 A RCD A RCD A A 1283904 T01 B ...

Reviews: