background image

6

106128-2-

AA

 (A)

Kohler Co., Kohler, WI

5. TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

1.

Poor flush or poor rim
wash.

A. Low tank water level.

A. Adjust tank water level screw.

wash.

B. Undersize supply.

B. Install 1/2” supply.

C. Supply stop not fully open.

C. Fully open supply stop.

D. Low bowl water level.

D. Adjust bowl water level.

E. Volume control not properly adjusted

E. Increase flow by turning upward.

F.

Clogged trapway or rim holes.

F.

Unclog trapway or clean rim
holes.

G. Clogged soil pipe or vents.

G. Unclog soil pipe or vent pipe.

2.

Excessive noise.

A. Plunger needs lubrication.

A. Lubricate plunger with silicone

lubricant

B. Plunger needs replacing.

B. Replace plunger.

3.

Valve does not shut off
and water is flowing

A. Defective plunger.

A. Replace plunger.

and water is flowing
into the overflow.

NOTE: After tank is filled to
water level line, turn off sup-

B. Water level too high in tank.

B. Lower water level to below

rimfeed hose.

water level line, turn off su -
ply stop; see if water level
drops.

C. Leaky float ball.

C. Replace float ball.

D. Leaky float valve seat.

D. Replace seat washer.

4.

Bowl seal does not
recover.

NOTE M

b

d b

A. Seal screw needs adjusting.

A. Adjust seal screw.

NOTE: May be caused by
temporarily reduced water
pressure.

B. Clogged soil pipe or vents.

B. Unclog soil pipe or vent pipe.

5.

Toilet flushes by itself.

A. Line pressure surges activate float

valve.

A. Install pressure surge suppressor.

B. High water pressure.

B. Install pressure regulator.

6.

Toilet overflows.

A. Toilet is clogged.

A. Use plunger to unclog toilet.

Summary of Contents for WELLWORTH WATERGUARD K-3520

Page 1: ...e dimensions are nominal and conform to tol erances by ANSI standards A112 19 2 PRODUCT REQUIREMENTS Since all toilets do not have the same supply rough in you may have to change the location of the s...

Page 2: ...fixture for any sign of damage before removing the existing toilet Turn off the water supply Flush the toilet and sponge out all remaining water from the tank and bowl Disconnect the supply valve and...

Page 3: ...T Bolts INSTALL TOILET GASKET Position the toilet upside down on padding Firmly attach the gasket around the toilet outlet If you are using a gasket with an integral plastic sleeve position the gasket...

Page 4: ...duct damage Overtightening may cause breakage or chipping of the vitreous china bowl or tank Fig 8 Tank Bolt Gasket Washer Brass Nut CONNECT SUPPLY SHUT OFF VALVE NOTICE Read this section carefully be...

Page 5: ...ke sure the refill tube is inserted into the overflow tube Check that the water level is at the water line inside the toilet tank If the level is off hold the middle of the float rod and carefully ben...

Page 6: ...e plunger 3 Valve does not shut off and water is flowing A Defective plunger A Replace plunger and water is flowing into the overflow NOTE After tank is filled to water level line turn off sup B Water...

Page 7: ...Co distributor please write us directly at Kohler Co Attn Customer Service Department 444 Highland Drive Kohler WI 53044 U S A FOURTH Include all pertinent information regarding your claim including a...

Page 8: ...8 106128 2 AA A Kohler Co Kohler WI...