How to Clean the Nozzles

Any debris or mineral build-up may cause the flow stream to become 

distorted or reduce the flowrate. To remove the debris or mineral 

build-up, run water through the watertile, press or rub the fingers back 

and forth across the rubber nozzles.

The handspray & shower head can be cleaned up by the same way.

If need to clean watertiles further. Grasp the faceplate(39) with the 

clips on the scraper(21) to take it off. Run water through the           

watertiles, firmly press or rub your finger back and forth across the 

rubber nozzles.

After cleaning, install the faceplate with the notch of faceplate being 

situated over the bulge on the supporter of nozzles. 

CLEANING INSTRUCTION

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with 

clean soft cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. 

which could adversely affect  the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings.

Mount the wall fixture bracket(12) by  anchors(8),  washers(9), screws 

(11). Make sure the bracket level and secure. Refer to Fig.8.

Apply tape or thread sealant to threads of G3/4" fittings(6). Install the 

inlet elbows(13) onto the fittings. Outlets of the elbows facing      

downwards.

Turn on the main water supply. Run water for about one minute to 

remove any debris.

Support the lower base(16) of the shower panel onto wall fixture 

bracket(12), referring to Fig.12. Hang the hook(14) which attached to 

upper base(15) under the washer(9), referring to Fig.10.

Connect the nut(40) to inlet elbows(13). Connect the hoses(18) with 

washers(17) to the nut. Note: The hose connecting to valve connector 

with HOT mark should attach to hot water supply.

Push back the shower panel. Unlock the hook. Carefully lift the 

shower panel. Riding the slot of the upper base onto the screw(8) 

from the back of the washer(9). At the same time, insert the lower 

base into the behind of the wall fixture bracket, referring to Fig.14.  

Position the shower panel. Tighten the butterfly nut(7) to secure the 

shower panel.

Install shower bracket(19) onto tube assy(20), referring to Fig.14.

Reinstall the upper cover and the lower cover.

Note

 The lower cover is with magnet. The magnet is used to hold 

the scraper(21).

Fig.7

Fig.8

8

12

9 11

Fig.9

Fig.10

Fig.11

Fig.12

6

13

14

9

15

12

16

Fig.13

Fig.14

19

20

8 9 7

Fig.15

Magnet

21

21

Clip

39

Bulge

Fig.23

Fig.24

Fig.25

13

40

17

18

Summary of Contents for Waterlite tower 3866

Page 1: ...ONS ROUGH IN DIMENSIONS 1368 809 Shower Panel OPERATION CONDITION Dounting Dimensions 225 300 143 812 Supply Pipes Handspray Not for 3866 G3 4 530 736 51 3866 3872 SHOWER PANEL PIPES Shower Head Not for 3866 1100 65 150 Floor of bath room 65 243 57 G1 2 280 280 G3 4 455 30 30 G1 2 Recommended mounting height Planform Inlet Elbows 3010558 Tube Assy 3008557 Shower Head Not for 3866 3008426 Clamp 832...

Page 2: ...40 HOT COLD 150mm Fig 1 Fig 2 1 2 1 3 Disassemble Upper and Lower Covers Unscrew the screws 1 with screwdriver Take off the upper cover 2 and the lower cover 3 Fig 3 5 4 Fig 4 20 40 Fig 5 Fig 6 Ø8 Ø8 150 Supply connnectors 8 9 10 7 6 6 3007327 Shelf 3008256 Elbow Connector F G1 2 3008520 Screw 3008555 Handspray Not for 3866 1046290 Hex Wrench 3008144 Scraper 3010558 Tube Assy 3007160 Cap 837192 Sc...

Page 3: ...ke sure the bracket level and secure Refer to Fig 8 Apply tape or thread sealant to threads of G3 4 fittings 6 Install the inlet elbows 13 onto the fittings Outlets of the elbows facing downwards Turn on the main water supply Run water for about one minute to remove any debris Support the lower base 16 of the shower panel onto wall fixture bracket 12 referring to Fig 12 Hang the hook 14 which atta...

Page 4: ...ND MAINTENANCE Clean Thermostatic Cartridge Very hard water can obstruct the filters on thermostatic cartridge and reduce the flow of water Please clean the cartridge as follows Shut off the water supplies of the faucet and open the flow valve then proceed to remove the cartridge The cartridge is sense organ please be careful Disassemble the upper and down covers Loosen the butterfly nut Hang the ...

Reviews: