background image

3866    3872        SHOWER PANEL

   

                                                                          

     1075723-2A-D                              

                                       

                                                7   

  

   

                                                                               

     1075723-2A-D                                  

                                                                                                                  2   

  

INSTALLATION

How to Install the Shelves

Before installing the shower panel, Install the shelves(5) first. Install 

the shelves with the T-tab of its being situated into the T-slot of the 

extrusion. Secure it by screws(4).

How to Install the Shower Panel

Install G3/4" male supply fittings(6, not provided). Hot one must be 

located on the left. The recommended height from center of the 

fittings to the finished floor of the bathroom is 1100mm. The fittings 

are spaced 150mm apart from center to center, level, and vertical to 

the finished wall. And fittings extend beyond the finished wall 

20-40mm.

Cut crosses at the hot and cold water supply connectors on the 

mounting templet with knife.

Put the mounting templet over the G3/4" male supply fittings. Position 

it. Stick it onto the finished wall with adhesive tape. Drill three holes 

(diameter 8mm) on the finished wall as the locations on the mounting 

templet, as Fig.5 shown.

Take off the mounting templet. Install the anchor(8), screw(10), 

washer(9) and butterfly nut(7). 

20-40

HOT

COLD

150mm

Fig.1

Fig.2

1

2

1

3

Disassemble Upper and Lower Covers

Unscrew the screws(1) with screwdriver. Take off the upper cover(2) 

and the lower cover(3).

Fig.3

5

4

Fig.4

20-40

Fig.5

Fig.6

Ø8

Ø8

150

Supply connnectors

8

9

10

7

6

6

3007327

Shelf

3008256

Elbow Connector F-G1/2˝

3008520

Screw

3008555**

Handspray

(Not for 3866)

1046290

Hex Wrench

3008144

Scraper

3010558**

Tube Assy

3007160**

Cap

837192

Screw

832940**

Washer

871584

Stopper

865150

Nut

3008304

Thermostatic Valve

1108609**

Shower Bracket

3008240

Washer

3008557**

Shower head

(Not for 3866)

3007775

Screw

3008407

Wall Fixture 

Bracket

3007799

Screw

3007798

Anchor

3008162**

Temperature 

Handle Assy

3010455

Screw

3007075

Washer

1248781**

Hose

871241

Spline Adapter

3010189

Valve

3008253

Elbow Connector F-G1

˝

831306

Screw

3008313**

Flow handle

3008338

Screw

3008315**

Flow handle

3008314**

Flow handle

3007166

Tube Cap

3007774

Screw

831306

Screw

3008142

Washer

3007325**

Watertile

3008348

Thermostatic 

Valve Assy

3007735

Flow Valve Assy

3008141

Nut

3010771**

Straight

Tube Assy

3008341

Inlet Elbow

**Color code must be specified when ordering

 

SERVICE PARTS

                                                 Shower Panel

3008241

Lower Cover

834327

Washer
831752

Check Valve
1191066

Nut

831289

Washer

831289

Washer

831289

Washer

3007157

Upper Cover

3007776

Butterfly Nut

Summary of Contents for Waterlite tower 3866

Page 1: ...ONS ROUGH IN DIMENSIONS 1368 809 Shower Panel OPERATION CONDITION Dounting Dimensions 225 300 143 812 Supply Pipes Handspray Not for 3866 G3 4 530 736 51 3866 3872 SHOWER PANEL PIPES Shower Head Not for 3866 1100 65 150 Floor of bath room 65 243 57 G1 2 280 280 G3 4 455 30 30 G1 2 Recommended mounting height Planform Inlet Elbows 3010558 Tube Assy 3008557 Shower Head Not for 3866 3008426 Clamp 832...

Page 2: ...40 HOT COLD 150mm Fig 1 Fig 2 1 2 1 3 Disassemble Upper and Lower Covers Unscrew the screws 1 with screwdriver Take off the upper cover 2 and the lower cover 3 Fig 3 5 4 Fig 4 20 40 Fig 5 Fig 6 Ø8 Ø8 150 Supply connnectors 8 9 10 7 6 6 3007327 Shelf 3008256 Elbow Connector F G1 2 3008520 Screw 3008555 Handspray Not for 3866 1046290 Hex Wrench 3008144 Scraper 3010558 Tube Assy 3007160 Cap 837192 Sc...

Page 3: ...ke sure the bracket level and secure Refer to Fig 8 Apply tape or thread sealant to threads of G3 4 fittings 6 Install the inlet elbows 13 onto the fittings Outlets of the elbows facing downwards Turn on the main water supply Run water for about one minute to remove any debris Support the lower base 16 of the shower panel onto wall fixture bracket 12 referring to Fig 12 Hang the hook 14 which atta...

Page 4: ...ND MAINTENANCE Clean Thermostatic Cartridge Very hard water can obstruct the filters on thermostatic cartridge and reduce the flow of water Please clean the cartridge as follows Shut off the water supplies of the faucet and open the flow valve then proceed to remove the cartridge The cartridge is sense organ please be careful Disassemble the upper and down covers Loosen the butterfly nut Hang the ...