PRODUCT INFORMATION
INDEX
DATE
Dep. 2
IC-G-D-33-002e
A
July 2013
DESCRIPTION OF THE GIS IGNITION SYSTEM
1/7
1. DESCRIPTION
The ignition system manages and controls the ignition of the mixture in the combustion chamber. Firing must be
accurately coordinated with the rotation of the engine and the movement of the valves of each cylinder.
Two GIS ignition unit models are used by
Kohler
:
-
GIS ignition unit
-
GIS CSA ignition unit
Both units have the same performance in operation. The only difference of the two units lies in the housing;
76.64.607 up to 60ºC and 76.64.605 up to 70ºC.
The GIS ignition system is made up of the following components:
1. GIS ignition module
2. Display
module
3. Hall effect pickup and wiring
4. Two magnetic pickups and wiring.
5. Reset
pin
6. Reference
magnet
7. Primary
wiring
8. Coils
9. Secondary
wiring
Fig. 1 – GIS ignition unit
2.5.1
O&M_2.002211.810_A_10_2016