PRODUCT INFORMATION
INDEX
DATE
Dep. 2
IO-C-M-25-011e
May 2006
MAINTENANCE OF THE CRANKCASE GAS
RECIRCULATION SYSTEM
2/3
1.2. Inspecting the installation
-
Detach the hose clamps and wash any oil condensate and water out of the hose.
-
Clean the pressure control valve.
1.3. Performing the start-up procedure
-
Carry out the operations of a normal start-up (see IT-C-A-25-024e). If the red indicator is fully extended, push
it down with your finger, before starting the engine.
-
Record the crankcase pressure with the engine on load and the time (number of hours of operation) for the
next filter change. Set the control valve at an initial crankcase pressure of minus 4mbar. This valve shall not
be readjusted until the filtering cartridge is changed again; therefore, we recommend removing its operating
lever.
1
Crankcase
4
Pressure control valve
2
Blow-by gas breather
5
Oil return line
3
Gas recirculation filter
6
Connecting hoses
The graph below shows the crankcase pressure variation in relation to the hours of operation of the filtering
cartridge.
9 0
0
5 0
3 2
70
50
2
°C
90
7 0
160
°F
60
14 0
1 20
40
90
°C
12
0
11 0
1 00
0
50
32
1
0
° C
7 0
160
° F
6 0
1 40
1 20
4 0
70
50
3
7
BAR S
6
5
4
90
° C
12
0
11 0
1 00
R
6
2
1
MUST B E I NSTA LLE D P ER FORM CP U-95 II
ALTRON IC,INC YOU NGSTOWN,OHIO
CLASS I, GROUP D, DIV .2T4
LORS QU E LES.
COUVE RCLE BIE N FERME
AVER TISSE ME NT:GAR DER LE
WH ILE C IRC UITS ARE LI VE.
WAR NIN G:KEEP COVE R TIGHT
INST ALLECONFORMEMA NT CP U-95 II
CER TIFIED
R
U.S . PA TENT NO.5.623.209
IGNI TI ON SYSTEM
ALTRONIC CPU-95
PART NO.
R
S /N
4
3
5
6
+3 mbar
0 mbar
-4 mbar
PRESION RELATIVA
HORAS DE FUNCIONAMIENTO
PRESION DE CARTER
RELATIVE PRESSURE
HOURS OF OPERATION
CRANKCASE PRESSURE
5.2.14
O&M_2.002211.810_A_10_2016