2. Make sure of h according to dimensions of bowl and then
locate the installation hole of fixing bracket. Mark on the
wall for appropriate position for fixing bracket, and drill four
holes with diameter of 10mm and depth of 80mm with
churn drilling as shown in illustration, and fill in the holes
with bulge screw and tighten the screw to set the fixing
bracket.
Note: Ensure the fixing bracket to remain level.
2.
h
10mm
80mm
O
Fixing Bracket
Bulge Screw
Gasket
Spring
Nut
h
3. Put the tank onto the fixing bracket as shown in the right
figure and adjust the tank to level . Then tighten screws
with hex-head key.
it is a must to keep the tank level.
Note:
3.
Screw
Level
Tank
Tighten
Loosen
Medium
Allen Key
4. Connect with overflow pipe on the side when installing
K-78073K-PNE/K-78075K-PNE.
4. K-78073K-PNE/K-78075K-PNE
Overflow Pipe
5. Connect tap water braided tube on the top of water tank for
water supply as shown.
Note: 1. Ensure water tank internal valve is OFF.
2. Suggestion: connect a temporary rubber or plastic
hose on valve, flush water supply pipeline. Ensure
water is clean, no residual sand stone or fouling
inside pipeline.
5.
1.
2.
Water Pipe
Connecting Pipe
1288818-T01-B
Summary of Contents for REVE K-14042T-L