Kohler reserves the right to change marked dimensions without prior notice.
-5-
Floor Discharge Installation Method
There are three methods (A, B and C) for drainage pipe
installation. Loosen the knob open on the fixing frame, put
the drainage pipe into the fixing frame, then adjust and
tighten the knob lock . Fill the bottom of the drainage pipe in
the drainage hole .
"
"
"
"
A
B
C
open
lock
B
C
A
Discharge
Elbow
Discharge
Elbow
Discharge
Elbow
Water Tank
Bracket
Water Tank
Bracket
Water Tank
Bracket
Drain outlet
90mm, welding
90mm
Drain outlet
110mm
110mm
Drain outlet
110mm, welding
110mm
Drainage Pipe
Tank Bracket
Bottom of the Drainage Pipe
Drainage Hole
Fixing Frame
Knob
225
1
225
1
160
1
160
1
K-20341T-PNE
K-75890T-PNE
Method four:
Press from front
K-78073T-PNE/K-78073K-PNE/K-78074T-PNE/K-78074T-RES/K-78074T-ESS/K-78074T-VLS
K-78074T-VLSL/K-78074T-VL130/K-78074T-VL150/K-78074K-PNE/K-75075T-PNE/K-78075K-PNE
477
3
152
3
134
2
461
3
322
3
97
2
440
3
Installed with K-20341T-PNE
K-20341T-PNE
Method one:
Press from top
Method two:
Remote plate installation
Method three:
Remote installation
of mask
Air hose
Air hose
Air hose
Air hose
Pinch
plate
Pinch plate
Suggested faceplate
installation area
R1000mm
Suggested faceplate
installation area
R1000mm
60
1
Finished wall
23~72
At least
80mm gap
reserved
80mm
Finished Floor
Height to floor is decided by bowl.
K-23055T-PNE
155.5
1
51
1
1288818-T01-B
Summary of Contents for REVE K-14042T-L