background image

-1-

No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC

POST CODE 528137

2

528137

8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA POST CODE: 256410

8

256410

REVE

INSTALLATION INSTRUCTIONS

VITREOUS CHINA FLOOR-STANDING TOILET

K-20766T-S/K-20767T-S/K-20768T-S/K-14042T-L/K-14042T-R

·

·

·

Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
warranty information -

.

please leave instructions for the

consumer

·

·

·

-

·

ORDERING INFORMATION

REVE WF Toilet (HT200 PNE IWT)......................K-20766T-S

Includes Reve Floor Standing Toilet .....................K-5038T
Includes HYDRO-TOWER 200 PNE

In-Wall Tank W/O Frame .............K-78074T-RES

Includes Reve QC Seat ................................K-17183T-CP

REVE WF Toilet (HT300 PNE IWT)......................K-20767T-S

Includes Reve Floor Standing Toilet .....................K-5038T
Includes HYDRO-TOWER 300 PNE

In-Wall Tank W/O Frame .............K-78077T-RES

Includes Reve QC Seat ................................K-17183T-CP

REVE WF Toilet (HT300 MEC IWT) .....................K-20768T-S

Includes Reve Floor Standing Toilet .....................K-5038T
Includes HYDRO-TOWER 300

In-Wall Tank W/O Frame .............K-10611T-RES

Includes Reve QC Seat ................................K-17183T-CP

Maxispace Toilet with Paper Holder ......................K-14042T-L

Maxispace Cabinet with Paper Holder.............K-24902T-L
Reve Floor Standing Toilet ...................................K-5038T
Reve QC Seat...............................................K-17183T-CP
305mm S-Trap ......................................................1249428

Maxispace Toilet with Paper Holder .....................K-14042T-R

Maxispace Cabinet with Paper Holder ............K-24902T-R
Reve Floor Standing Toilet ...................................K-5038T
Reve QC Seat...............................................K-17183T-CP
305mm S-Trap ......................................................1249428

(

200

)................K-20766T-S

.........................................K-5038T

200

....................K-78074T-RES

........................................K-17183T-CP

(

300

)................K-20767T-S

.........................................K-5038T

300

....................K-78077T-RES

........................................K-17183T-CP

(

300

)................K-20768T-S

.........................................K-5038T

300

...........................K-10611T-RES

........................................K-17183T-CP

(

).....................................K-14042T-L

(

) ...................K-24902T-L

.............................................K-5038T

............................................K-17183T-CP

305mm

...........................................1249428

(

) ....................................K-14042T-R

(

) ..................K-24902T-R

.............................................K-5038T

............................................K-17183T-CP

305mm

...........................................1249428

©

©

Copyright Kohler China Investment Co., Ltd. 2018

2018

1258187-T01-B

Summary of Contents for REVE K-14042T-L

Page 1: ...ORMATION REVE WF Toilet HT200 PNE IWT K 20766T S Includes Reve Floor Standing Toilet K 5038T Includes HYDRO TOWER 200 PNE In Wall Tank W O Frame K 78074T RES Includes Reve QC Seat K 17183T CP REVE WF Toilet HT300 PNE IWT K 20767T S Includes Reve Floor Standing Toilet K 5038T Includes HYDRO TOWER 300 PNE In Wall Tank W O Frame K 78077T RES Includes Reve QC Seat K 17183T CP REVE WF Toilet HT300 MEC ...

Page 2: ...below the tank install one before installing the new toilet 2 There s no need for S trap toilet users to order P trap 1036901 NOTICE 254mm 305mm P 1036901 1 2 P 1036901 NOTES Observe all local plumbing and building codes Shut off the water supply Seat post holes are on 200mm centers 57mm passageway Ensure that the new drain has the correct roughing in dimension This toilet has a 305mm roughing in ...

Page 3: ... 185 92 390 185 155 With 1226681 S trap 1226681 With 1036901 P trap 1036901 Finished Wall Finished Wall UNIT mm Reference Value 508 240 246 1623 5 888 888 345 150 314 430 370 5 730 Finished Floor K 14042T L K 14042T R 3 1258187 T01 B ...

Page 4: ... 4 150 508 200 365 700 200 550 365 550 390 350 185 305 350 185 550 390 Fig 1 1 Kohler reserves the right to change marked dimensions without prior notice 1258187 T01 B ...

Page 5: ...Turn the water supply off before installing the new toilet 2 Install the concealed tank system in wall before decorating the wall 3 Install the tank system per tank s installation instructions 4 Refer to installation instructions of in wall tank for SKU of faceplate 1 2 3 4 INSTALLATION WITH IN WALL TANK INSTALLATION WITH IN WALL TANK Fig 2 2 1258187 T01 B ...

Page 6: ...0 200 200 O utlet 155 S trap Outlet 185 Water Supply P trap 2 3 2 Position the template and align with drain hole or wall 3 Mark down the position of foot and 2 holes 4 Drive holes on ground with the driver of 10mm 3 8 then insert anchor to holes 4 10mm Fig 4 4 Drain Hole Foot Hole Fig 5 5 3 8 10mm 1258187 T01 B ...

Page 7: ...ach connection pipe For P trap 1 Attach inlet pipe which set aside the length to the concealed tank 2 Attach outlet pipe to the toilet 3 You may apply some lubricant to help connect smoothly 4 Please tilt the outlet pipe a little after it is installed to prevent water storage See Fig 7a See Fig 7b 6A P 1 2 3 7a 4 7b Inlet Outlet Fig 7a 7a Fig 7b 7b 1 1258187 T01 B ...

Page 8: ...irmly Apply soap water around rubber seal for easier mounting Carefully align and lower backward the bowl Apply weight to the bowl rim to let the outlet insert into plastic trap 7 Outlet Tank outlet Bowl inlet 8 Plastic Trap Fig 9 9 1258187 T01 B ...

Page 9: ...nterfering with flush button when opening the toilet seat Note 9 10 Fig 11 11 Fig 12 12 9 8 Carefully thread the screws into the brackets until toilet is secure Alternately tighten left and right sides to prevent pulling the toilet off center Install cap to cover screw Do not overtighten 8 Fig 10 10 Cap Screw Bushing 1258187 T01 B ...

Page 10: ...Toilet overflows 7 Toilet does not activate A Reconnect the push button A Push button is not connected to lift rod or flush valve 2 Fill valve continues to run allowing water to enter tank 3 Incorrect water level height A Foreign particles lodged under the float valve seal located under fill valve cap B Fill valve seal located under float valve cap may be cracked or split C Water leaking past flus...

Page 11: ...1 A A A B C D E A 1 8 1 8 B C D E 2 3 A A 7 A A 4 A A 5 A B C D A B C D 6 A B A B 11 1258187 T01 B ...

Page 12: ...ive cleaners or solvents Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage 0 C...

Page 13: ...06T PNE HYDRO TOWER 200 PNE IWT 2 6 4 0L K 20006K PNE HYDRO TOWER 200 PNE IWT 3 0 4 5L K 20007T PNE HYDRO TOWER 200 PN IWT W FRAME 3 5 5 0L VEIL WH K 20007T VLS HYDRO TOWER 200 PN IWT W FRAME 3 5 5 0L ODEON WH K 20007T DNSW HYDRO TOWER 200 PN IWT W FRAME 3 5 5 0L ODEON WH K 20007T DNW HYDRO TOWER 200 PN IWT W FRAME 3 5 5 0L VIA WH K 20007T VABW HYDRO TOWER 200 PN IWT W FRAME 3 5 5 0L REVE WH K 200...

Page 14: ...K 78075K PNE K 20341T PNE K 75890T PNE K 23055T PNE 0 Design And Installation Concept Of In wall Tank Installation of in wall tank is much easier and nice looking comparative to that of traditional tank Meanwhile the space layout will be more reasonable due to the application of in wall tank pipes and connectors The most remarkable advantage of in wall tank is that the installation will never be l...

Page 15: ...C C C C C C C C 1 55 1 45 Full flushing volume Half flushing volume 6 L 3 L 6 L 3 L 0 0 0 0 K 20007T PNE K 20007K PNE K 78074T PNE K 78074K PNE K 78074T VLS K 78074T VLSL K 78074T VL130 K 78074T VL150 K 20007T VLS K 20007T DNSW K 20007T DNW K 20007T VABW K 20007T RES K 78074T RES K 78074T ESS K 20008T PNE K 20008K PNE K 78075T PNE K 78075K PNE Full flushing volume 4 5L Half flushing volume 3 L 0 0...

Page 16: ...07T RES K 20007K PNE K 20008T PNE K 20008K PNE Method four Press from front 478 3 35 2 100 2 180 3 230 3 90 0 5 438 3 150 185 Air hose Finished floor Air hose Air hose Pinch plate Suggested faceplate installation area R1000mm Suggested faceplate installation area R1000mm Installed with K 20341T PNE K 20341T PNE Method one Press from top Method two Remote plate installation Method three Remote inst...

Page 17: ...k Bracket Bottom of the Drainage Pipe Drainage Hole Fixing Frame Knob 225 1 225 1 160 1 160 1 K 20341T PNE K 75890T PNE Method four Press from front K 78073T PNE K 78073K PNE K 78074T PNE K 78074T RES K 78074T ESS K 78074T VLS K 78074T VLSL K 78074T VL130 K 78074T VL150 K 78074K PNE K 75075T PNE K 78075K PNE 477 3 152 3 134 2 461 3 322 3 97 2 440 3 Installed with K 20341T PNE K 20341T PNE Method o...

Page 18: ...r board inside water tank first as shown Then remove support block and plug above bracket assembly 1 2 Insert the frame screw and screw cap in the holes of fixing frame lock the frame screw with nut then tighten the frame screws on the fixing frame with medium Allen key as shown in illustration A Tighten the bolts with medium Allen key as shown in illustration B and adjust the height of the adjust...

Page 19: ... bulge screw and tighten the screw 3 10mm 80mm Bulge Screw Gasket Bulge Screw Cap Bolt 4 Tighten the hexagonal long screw with medium Allen key as shown in illustration A Tighten the screw of adjustable brackets with medium Allen key as shown in illustration B and tighten the long screw with spanner NOTE Ensure the tank to remain level 4 A B Hexagonal Screw Loosen Tighten Level Medinm Allen Key Ad...

Page 20: ...sand stone or fouling inside pipeline 3 1 2 B Floor Discharge Installation Method B 1 There are three methods A B and C for drainage pipe installation Loosen the knob open on the fixing frame put the drainage pipe into the fixing frame then adjust and tighten the knob lock Fill the bottom of the drainage pipe in the drainage hole 1 A B C open lock B C A Discharge Elbow Discharge Elbow Discharge El...

Page 21: ...k when pressing from top a Remove top plate then install the rectangular shield on the top of the tank and tighten the screw to fix the mask to the tank A a Air hose Suggested faceplate installation area R1000mm Method three Remote installation of mask Method four Press from front Air hose Pinch plate Finished wall Air hose Pinch plate Suggested faceplate installation area R1000mm Method one Press...

Page 22: ...rom the front of the tank and meanwhile reserve the access panel Fix the four plates with screws and then fix the support board No direct contact between the faceplate and the tank 7 20mm thickness recommended for the wall of the pinch plate Note Recommended installation hole size of X mm to remote plate installation 297 157 C 7 20mm X mm 297 157 Cover Top Cover Front At least 80mm gap reserved 80...

Page 23: ...146 X 41 mm 146 X 41 mm 41 146 2 0 2 0 Pinch Plate Wall Thickness 7 40mm 7 40mm Adjust length of pinch plate in accordance with wall thickness At least 80mm gap reserved 80mm 2 Tighten the long screw into the holes of the tank bracket and cover the drainage hole with the big cap cover the inlet hole with the small cap 2 Long Screw Water Inlet Drainage Hole Big Cap Water Tank Bracket Small Cap C In...

Page 24: ...ve appropriate space according to the distance from the back of the tank to the inlet hole on the wall 1 Inlet Pipe Drainage Pipe Mask Big Cap Small Cap Access Panel Access Panel 3 Install the big and small leak proof gaskets on inlet pipe and outlet pipe then install it to corresponding pipes on the toilet tank 3 Small Leak proof Gasket Inlet Pipe Drainage Pipe Big Leak proof Gasket 2 Inlet Pipe ...

Page 25: ...rit level to ensure the lavatory to remain level 5 Spirit Level E Faceplate Installation E 1 1 OPEN When tighten four locknuts on supporting board adjust to OPEN mark as shown Supporting Board Locknut Gasket Long Screw Reversed Lock Hexagonal Nut Decoration Cap 6 Install the reserved lock gasket hexagonal nut and decoration cap onto long screw according to the order shown in the illustration Pleas...

Page 26: ...ersed lock on supporting board then push the cover and lock it The installation shall begin from bottom to top Note 3 Faceplate Lock Faceplate Supporting Board Connect to air hose Fastener 4 It is ready to use when connected to water supply after installation Reserve access panel at front or top of the tank in remote installation Note 4 Half Flush Button Full Flush Button 2 K 23055T PNE installati...

Page 27: ... after installation Reserve access panel at front of the tank in remote installation 4 5 5 How to remove Push Up Pull Out Pull Out Installation For In wall Tank Without Frame A Installation of In wall Tank A 1 Remove in wall tank from packing box Remove front cover board or top cover board inside water tank first as shown Then remove support block and plug above bracket assembly 1 Cover Top Cover ...

Page 28: ...tank onto the fixing bracket as shown in the right figure and adjust the tank to level Then tighten screws with hex head key it is a must to keep the tank level Note 3 Screw Level Tank Tighten Loosen Medium Allen Key 4 Connect with overflow pipe on the side when installing K 78073K PNE K 78075K PNE 4 K 78073K PNE K 78075K PNE Overflow Pipe 5 Connect tap water braided tube on the top of water tank ...

Page 29: ...Method three Remote installation of mask Air hose Air hose Air hose Pinch plate Pinch plate Suggested faceplate installation area R1000mm Suggested faceplate installation area R1000mm Finished wall 23 72 At least 80mm gap reserved 80mm 6 According to different faceplates there are different installations of access panel as below 6 b Cut apart the cable of the air hose and pull it out from the rect...

Page 30: ...reserved 80mm Air hose Pinch plate Finished wall Supporting Board Air hose Finished wall 72 7 20mm recommended 7 20mm 10 Hole through hose 10 10 Depth 16 Space reserved 10 16 297 157 2 0 2 0 2 0 2 0 2 0 2 0 Pinch plate installation Screw Air hose Pinch plate Pinch plate Finished wall Faceplate Supporting Board C Method four Cut apart the cable of the air hose Pull it out from the front of the tank...

Page 31: ...l the air hose to the panel Reserve access panel at front to ensure removal and installation of cover Recommended installation hole size of 146 X 41 mm 146 X 41 mm 41 146 2 0 2 0 Pinch Plate Wall Thickness 7 40mm 7 40mm Adjust length of pinch plate in accordance with wall thickness At least 80mm gap reserved 80mm 9 Fix faceplate according to step E and then it is ready for use Reserve access panel...

Page 32: ...E OF THE OUTLET VALVE Faceplate Faceplate Connect to air hose 3 Dismantle supporting board as shown 3 2 Pay special attention when dismantle supporting board 4 lock nuts all bolts shall align with OPEN mark 2 OPEN 4 Open close water supply Rotate valve switch to open close water supply as shown 4 Valve Close Open Supporting Board Locknut 1288818 T01 B ...

Page 33: ...sh aside the pivot snaps of the big flush and small flush towards lower left to fix back the bracket Lock the snap Note 7 Lever Snap Snap Locked Fastener Fastener 8 Hold fastener by hand as shown pull the top of fastener along the direction of arrow Then remove fastener 8 Snap 5 Unscrew the nut of the metal weaved hose and push the connector of the inlet valve as shown to remove the inlet valve 5 ...

Page 34: ...first then loosen and take out the tighten nut and wash the waste on filtration net with clean water Then reset the tighten nut to the original position A Tighten Close Open Corner Open A Tighten Close C Filtration Net B Press for Top 9 Pull discharge valve along the arrow direction as shown to remove discharge valve 9 Outlet Valve 1288818 T01 B ...

Page 35: ...ed Readjust the water level The floating box of the inlet valve is blocked by wastes so the water is leaked from the overflow pipe A No water supply B The water supply stop is closed Readjust the position of other parts to avoid contacting the floating box when it is functioning A Wait for restoration of water supply B Open the water supply stop Readjust the position of other parts to avoid contac...

Page 36: ...A B A B 24 1288818 T01 B ...

Reviews: