Lubricants
Silicone based lubricants must only be used on the rubber seals.
Caution! Oil based or other lubricant types may cause rapid deterioration of seals.
Cleaning
The chrome plated parts should be cleaned using a mild washing up detergent or
soap solution, rinsed and then wiped dry with a soft cloth.
Warning! Many household cleaners contain abrasive and chemical substances, and
should not be used for cleaning plated or plastic fittings.
Do not use descalents on this product.
Part Number
Description
1578.046
Thermostatic Cartridge
Maintenance Procedure - Thermostatic Cartridge
Removal (Refer to Figure 1)
1.
Isolate the supplies to the shower control, and open the flow control to release
pressure and to assist the draining of residual water.
2.
Remove the temperature knob assembly, using the 3 mm A/F hexagonal wrench
(supplied). Do not remove the temperature hub.
3.
With removal clip still in place, unscrew the head nut using a 35 mm A/F wrench.
This will release the body shroud and also begin to draw the Thermostatic
cartridge out of the shower control body.
Warning:
some residual water may be released.
4.
Note which inlet aligns with the hot (marked H and coloured red) lug on cartridge.
5.
Pull the Thermostatic cartridge free of the shower control body.