7
1057614-W2-D
Flow Control:
Rada Exact-3 B shower controls have integral flow control; no other user-
operated flow controller should be used with this shower control.
Outlet:
The outlet connector is designed to accept:
Flat-faced / flanged unions (maximum flange diameter 20 mm); use flat-faced
insert (408 71, supplied)
15 mm pipework; use compression olive (542 10).
Connections:
Rada Exact-3 B
- Inlets and Outlet: 1/2” BSP external union or 15 mm
compression (nut and olive provided).
Inlet/ Outlet Options:
INLETS: OUTLET:*
Exact-3 B
Any Configuration
bottom,
top
*
Products are supplied in the format shown in bold.
Standard Connections
are:
hot
-
left (marked red)
cold
-
right
(marked blue)
Outlet
-
top
(can be altered to bottom outlet if
required, refer to
INSTALLATION
)
Note!
Should the supplies be reversed then the shower control will not be able
to control temperature. This can be corrected by reversing the position of the
Thermostatic cartridge within the control body, as described in
INSTALLATION
.
All models can operate in any plane, and may be inverted if necessary for supply
pipework layout convenience, provided hot and cold pipework are connected to
the appropriately marked inlets (hot - red, cold - blue).