2
TT-585 3/95
6. Secure strip heater assemblies to stator with lock
nuts (X-101-8). Position strip heaters with the AC
terminals closest to the end bracket of the
generator set. See Figure 1.
7. Open circuit breaker to AC power source. With
customer-supplied leads and terminals, connect
strip
heaters
to
AC
voltage
source
using
appropriate wiring diagram in Figure 2.
8. Replace junction box side panels.
9. Close circuit breaker to AC power source.
10. Reconnect generator set to load by closing line
circuit breaker or reconnecting output leads to
transfer switch. Reconnect engine starting battery,
negative (--) lead last.
3 in.
(76 mm)
+/- 0.25
6 in.
(152 mm) +/- 0.25
Screw *
(X-465-8)
Washer
(X-25-40)
Strip
Heater
(291269)
Nut, Hex *
(X-81-1)
Nut, Lock
(X-101-8)
Bottom of Stator
Assembly
See Side & Top Views
Below
End View
* Hand-tighten only
End Bracket
End
1 in.
(25.4
mm)
5-1/4 in.
(133.35
mm)
Drill Four 9/32 in. (7.14 mm) Holes in Stator Shell
Strip
Heater
(291269)
Side View
Top View
Install AC Lead
Terminals Perpendicular to Strip Heater
Y-253000-D
Figure 1.
Generator Heater Installation
CB-272000
120 Volt Connection Diagram
240 Volt Connection Diagram
120 Volt
Strip Heater
(291269)
120 Volts AC
240 Volts AC
120 Volt
Strip Heater
(291269)
120 Volt
Strip Heater
(291269)
120 Volt
Strip Heater
(291269)
Figure 2.
Heater Kit Wiring Diagrams
Parts List
KITS: PA-253213/PA-253213-SD
Qty.
Description
Part Number
8
Washer, plain
X-25-40
4
Nut, elastic stop
X-101-8
4
Screw, 1/4-20 x 1 1/4
X-465-8
4
Nut, spiral lock
X-6210-2
2
Heater, strip
291269