Servicing
Warning! There are no user serviceable parts inside the shower. Servicing
of the shower must only be carried out by qualified, competent personnel
following the instructions provided in this guide and those provided with
any spare part. Before replacing any parts, ensure that the underlying cause
of the malfunction has been resolved.
Refit the components in reverse order.
Cleaning the Inlet Filter
Warning!
Isolate the electrical and water supplies before removing the cover.
2
4
5
3
6
1
Inlet
Connector
Assembly
Inlet Filter
Screws
Service
Tunnel
Screw
Cover
Hose
Washer
Remove the shower hose.
Note:
Retain the hose washer for further
use
Remove the three screws that hold the cover
on the shower and remove the cover.
Remove the service tunnel from the shower.
Use a suitable spanner to remove the filter
from the inlet connector assembly. Hold a
wrench across the flats of the inlet connector
assembly to prevent damage to the connector,
whilst removing the filter.
Remove the filter and rinse under a running tap
to remove any lodged particles. If necessary,
use a kettle descalent in accordance with the
manufacturer’s instructions.