background image

10

1493623-W2-A

Installation Requirements

Plumbing

1.  The plumbing installation must comply with all national or local water regulations 

and all relevant building regulations, or any particular regulation or practice 

specified by the local water supply company.

2. 

DO NOT

 use sealing compounds on any pipe fitting or joints.

3. 

DO NOT

 install the product in a position in which service access is limited.

4.  Decide on a suitable position for the shower (minimum distance of 200 mm from 

the ceiling to allow for cover fit and removal).

5.  The position of the shower and shower fittings must provide a minimum gap of 

25 mm between the showerhead and the spill over level of any bath, shower 

tray or basin and a minimum gap of 30 mm between the showerhead and the 

spill over level of any toilet, bidet or other appliance with a Fluid Category 5 

backflow risk (see diagram on page 11).

6.  The shower is suitable for installation within the shower area and is fitted with 

a pressure relief valve. It must be positioned over a water catchment area with 

the controls at a convenient height for the user.

7.  The shower must be fitted to a waterproof flat and even wall surface.

8.

  DO NOT

 fit the shower to the wall and tile up to the case.

9.

  DO NOT

 seal the gap between the shower and the wall surface.

10. The showerhead should be positioned so that it discharges down the centre 

line of the bath or across the opening of a shower cubicle.

11. The showerhead must be directed away from the shower unit, during normal 

use the showerhead must not spray directly on to the shower unit.

12.

 DO NOT

 apply excessive force to plumbing connections; always provide 

mechanical support when making plumbing connections. Any soldered joints 

should be made before connecting the shower.

13. This shower is not designed to be plumbed directly from the rear. For rear-entry 

supply, add an elbow to the supply pipe and connect as a rising or a falling 

supply.

14. If pipework and/or electrical cables enter the shower from the rear through a 

hole in the wall provision must be made to prevent water ingress back into the 

wall structure. 

15. Only use the inlet connector supplied with the shower. 

DO NOT

 use any other 

type of fitting.

16. A full bore/non restrictive servicing valve must be fitted in a readily accessible 

position adjacent to the shower to facilitate maintenance of the shower.

 

DO NOT

 use a valve with a loose washer plate (jumper) as this can lead to a 

build up of static pressure.

Summary of Contents for Mira Sport J03A

Page 1: ...1 1493623 W2 A These instructions must be left with the user Mira Sport 7 5 9 0 9 8 and 10 8 kW Installation and User Guide For SPARES ADVICE or REPAIRS please call us free on 0800 001 4040 UK only...

Page 2: ...ction concerning use of the appliance in a safe way and understand the hazards involved 2 Children shall not be allowed to play with the shower 3 DO NOT restrict the water flow from the shower outlet...

Page 3: ...t mode point handset away from body and make sure that the water temperature has stabilised before continuing to shower 16 Use caution when altering the water temperature always check the temperature...

Page 4: ...ering the shower 26 The water supplies to this product must be isolated if the product is not to be used for a long period of time If the product or pipework is at risk of freezing during this period...

Page 5: ...to familiarize yourself with the part names and to confirm that the parts are included Documentation 1 x Electric Shower 2 x Case Inserts 1 x Installation Guide and User Guide 1 x Installation Templa...

Page 6: ...iagram Inlet Connector Terminal Block Heater Tank Micro Switch L Micro Switch R Solenoid LED LED Housing Push Button Switch BROWN B GREEN D BLUE C RED K BROWN J BROWN G BLACK M BLACK L RED H BLUE E BR...

Page 7: ...tions and recommendations Follow all warnings cautions and instructions contained in this guide and on or inside the shower Mira Sport electric showers have separate controls for power selection and f...

Page 8: ...rical Variant 7 5 9 0 9 8 10 8 Nominal Power at 240 V ac 7 5 kW 9 0 kW 9 8 kW 10 8 kW Nominal Power at 230 V ac 6 9 kW 8 3 kW 9 0 kW 9 9 kW Recommended MCB Rating 32 A 40A 45A 45A Maximum Supply Cable...

Page 9: ...o conditional connection If the main electrical supply fuse is rated less than 80 Amps the local electricity supply company must be contacted to confirm if the electrical supply is adequate This range...

Page 10: ...rproof flat and even wall surface 8 DO NOT fit the shower to the wall and tile up to the case 9 DO NOT seal the gap between the shower and the wall surface 10 The showerhead should be positioned so th...

Page 11: ...red rawl plug and a no 8 x 1 countersunk brass or stainless steel screw should be used For other wall structures such as panels alternative fixings may be required A minimum of 3 fixing screws should...

Page 12: ...t be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provided with means for local...

Page 13: ...directly from the back Add an elbow to the supply pipe and connect it as a rising or falling supply 1 2 Using the installation template supplied mark the positions of the three fixing holes Note Ensu...

Page 14: ...to misaligned pipework or electrical cables Strip back sufficient outer cable insulation to enable routing to terminal block Fit an earth sleeve to the earth wire Tighten the screws in the terminal b...

Page 15: ...cked with the product LOW HIGH ECO POWER TEMPERATURE Do not use alternative screws to secure the cover This can cause internal damage to the appliance Do not seal around the back of appliance This com...

Page 16: ...Turn temperature control to the cold position Turn power control to low TEMPERATURE LOW HIGH ECO POWER 1 2 Switch on the electrical supply 3 Push START STOP button Light in the button illuminates 4 W...

Page 17: ...Temperature will rise slightly 10 5 10 secs COLD HOT 5 10 secs COLD HOT Turn power control to High LOW HIGH ECO POWER 11 Temperature will rise further 12 10 secs COLD HOT 5 10 secs COLD HOT 13 Adjust...

Page 18: ...temperature adjustments to stabilise and reach the showerhead Check the water temperature before entering shower Switch off the electrical supply Push the START STOP button to turn ON the appliance L...

Page 19: ...tone This is quite normal in use The Effect of Seasonal Changes Incoming mains water temperature is not constant throughout the seasons of the year i e cooler during the winter warmer during the summe...

Page 20: ...the showering temperature to increase Showering temperature will stabilise to within 6 C band if other outlets are opened whilst showering providing the minimum pressure does not fall below 70 kPa 0...

Page 21: ...ce if necessary ON ECO HIGH Water pressure below minimum required for shower operation Make sure incoming mains water stopcock and or shower isolating valve is fully turned on ON ECO HIGH Temperature...

Page 22: ...y ON ANY Possible failure of flow valve microswitch or heater tank Use a suitable device to check the continuity of the microswitch or heater tank and replace parts as necessary Water will not turn of...

Page 23: ...eep the showerhead nozzles clear or inspect the hose for blockage or internal external collapse can restrict the flow rate from the shower This may cause damage to the shower or result in the temperat...

Page 24: ...re removing the cover 2 4 5 3 6 1 Inlet Connector Assembly Inlet Filter Screws Service Tunnel Screw Cover Hose Washer Remove the shower hose Note Retain the hose washer for further use Remove the thre...

Page 25: ...438 7 5kW 1746 439 9 0kW 1746 440 9 8kW 1746 441 10 8kW Heater Tank includes microswitches 1746 449 Terminal Block 1746 436 Thermal Switch 1746 447 Outlet Connector A B B A A A 1746 442 1746 443 Flow...

Page 26: ...26 1493623 W2 A Notes...

Page 27: ...27 1493623 W2 A Notes...

Page 28: ...tenham Gloucestershire GL52 5EP 14648 Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase This guarantee only applies in the United Kingdom an...

Reviews: