26
Over Temperature at Control Sensor
1. Turn Digital Mixer off for 10 seconds. Turn back on and allow
15 seconds to reset.
2. If shower operation does not return to normal, make sure hot
and cold inlets are not reversed.
3. If shower operation does not return to normal, make sure inlet
filters and check valve cartridges are clean.
4. If shower operation does not return to normal, check the
water supplies to the valve are within the correct temperature
and pressure ranges. See “
Mira Pixel Installation Guide -
Specifications
”.
5. If problem still occurs, make a note of the error code and
contact our Customer Services Team.
Control Sensor
1. Turn Digital Mixer off for 15 seconds. Turn back on and allow
15 seconds to reset.
2. If shower operation does not return to normal, replace
Thermistor.
(To be performed by competent tradesperson
only!)
3. If problem still occurs, make a note of the error code and
contact our Customer Services Team.
Control Sensor or PCB Relay
1. Turn Digital Mixer off for 15 seconds. Turn back on and allow
15 seconds to reset.
2. If shower operation does not return to normal, replace
Thermistor.
(To be performed by competent tradesperson
only!)
3. If shower operation does not return to normal, replace PCB.
(To be performed by competent tradesperson only!)
4. If problem still occurs, make a note of the error code and
contact our Customer Services Team.
Error Codes
A specific problem relating to the electronic function of the shower will result in an
error code being displayed on the control.
FAULT DIAGNOSIS
Summary of Contents for Mira Pixel
Page 1: ...1 Mira Pixel Wireless Controller These instructions must be left with the user User Guide ...
Page 12: ...12 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...
Page 14: ...14 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...
Page 16: ...16 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...
Page 19: ...19 Press to exit back to Function Menu See section Exit the Function Menu Press to set ...
Page 22: ...22 Press to set and exit back to Function Menu See section Exit the Function Menu ...
Page 24: ...24 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...