Kohler Mira Event XS Installation & User Manual Download Page 40

40

1293809-W2-E

Customer Service

What to do if something goes wrong

If your product is not working correctly please refer 

to this manual for fault diagnosis and to check that 

it is installed and commissioned in accordance with 

our instructions. If this does not resolve the issue, 

our Customer Services team are here to help get you 

back up and running. To help us solve your problem 

quickly, please have your product name, power rating 

(if applicable) and date of purchase to hand.

Visit www.mirashowers.co.uk 

Visit  our  website  to  register  your  guarantee,  book  a 

service visit, diagnose faults and purchase products.

Spares and Accessories 

We stock a full range of spare parts and fi ttings and are 

all available to purchase either online or over the phone. 

Our online spare parts selector tool will help you quickly 

and easily identify the spare part for your product. 

Visit www.mirashowers.co.uk/parts-accessories

Replacements and Repairs 

In the unlikely event that your product needs a repair, 

our nationwide repairs and installation team are here to 

help. You can book a convenient date and time online. 

Scan the QR code to book a service visit 

now or visit www.mirashowers.co.uk/

support/repair-services/repair-service

We also off er a comprehensive replacement service 

for when your product needs a little refresh, visit our 

website or contact our team for more information on 

our replacement services.

Help us improve 

Your experience is important to us and your review 

(whether good, bad or otherwise) will be posted on 

Trustpilot.com immediately to help other people make 

more informed decisions.

Visit uk.trustpilot.com/review/www.mirashowers.co.uk

Mira is a registered trade mark 

of Kohler Mira Limited.

The company reserves the right 

to alter product specifi cations 

without notice.

EU Importer address

K/E S.A.S.

3 rue de Brennus,

93631, La Plaine Saint-Denis,

France

Registered Offi  ce: 

Cromwell Road,

Cheltenham, 

Gloucestershire 

GL52 5EP

14648

Guarantee 

Your  product  has  the  benefi t  of  our  manufacturer’s 

guarantee which starts from the date of purchase. 

This guarantee only applies in the United Kingdom 

and Republic of Ireland.

Activating Your Guarantee

Registering your guarantee is quick and simple. To 

ensure your product is covered, please register online .

Scan the QR code to activate your 

guarantee now or call 0800 5978551 

within 30 days of purchase (UK only).

 

What is Covered:

  ●  The  guarantee  applies  solely  to  the  original 

installation under normal use. 

  ●  The  product  must  be  installed  and  maintained 

in accordance with the instructions given in this 

guide.

  ●  Servicing must only be undertaken by us or our 

appointed representative.

  ●  Repair  under  this  guarantee  does  not  extend 

the original expiry date. The guarantee on any 

replacement parts or product ends at the original 

expiry date.

  ●  For  shower  fittings  or  consumable  items  we 

reserve the right to supply replacement parts only.

The guarantee does not cover:

  ●  Call  out  charges  for  non  product  faults  (such 

as damage or performance issues arising 

from incorrect installation, improper use, 

inappropriate cleaning, lack of maintenance, 

build up of limescale, frost damage, chemical 

attack, corrosion, system debris or blocked fi lters) 

or where no fault has been found with the product.

  ●  Water  or  electrical  supply,  waste  and  isolation 

issues.

  ●  Routine  maintenance  or  replacement  parts 

to comply with the requirements of Building / 

Plumbing / Electrical Standards or Schemes.

  ●  Compensation for loss of use of the product or 

consequential or indirect loss of any kind. 

  ●  Damage  or  defects  caused  if  the  product  is 

repaired or modifi ed by persons not authorised 

by us or our appointed representative.

  ●  Accidental or wilful damage. 

  ●  Products purchased ex-showroom display.

  ●  Disinfection  or  descaling  to  reduce  bacterial 

growth or contamination.

Need to get in touch? 
UK

T: 0800 001 4040

E: [email protected]

www.mirashowers.co.uk

Eire

T: 01 531 9337

E: [email protected]

www.mirashowers.ie

1473739-W6-A

© Kohler Mira Limited, June 2021

Summary of Contents for Mira Event XS

Page 1: ...1 1293809 W2 E Installation User Guide These instructions must be left with the user Mira Event XS Thermostatic Power Shower...

Page 2: ...ey are given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved 2 Children shall not be allowed to play with the shower 3 Cleaning and user ma...

Page 3: ...to shower 16 Switch the shower off at the electrical isolating switch when not in use This is recommended with all electrical appliances 17 Installation of the shower must be carried out in accordanc...

Page 4: ...or cut holes in the product other than instructed by this guide When servicing only use genuine Kohler Mira replacement parts 23 Always check the water temperature is safe before entering the shower...

Page 5: ...r to override the maximum temperature and select higher showering temperatures The button can be disabled if required The product is fitted with a 15 mm dual entry push fit inlet manifold which allows...

Page 6: ...s product has been designed for domestic use only Mira Showers guarantee this product against any defect in materials or workmanship for a period of one years from the date of purchase For terms and c...

Page 7: ...with the part names and to confirm that the parts are included 1 x Event XS T Thermostatic Power Shower 1 x Push Fit Release Tool 3 x Rubber Wall Plugs 3 x Fixing Screws 3 x Rubber Feet 4 x Case Inser...

Page 8: ...8 1293809 W2 E Dimensions are in millimetres 310 84 115 80 66 28 20 210 Dimensions...

Page 9: ...ithin 1 C with a 10 C change in the hot or cold water supply 1 4 2 The sensor effects a shut down to seepage in approximately 2 seconds if the cold supply fails 1 4 3 Shut down to seepage is achieved...

Page 10: ...ect the perceived noise level solid walls will provide a quieter operation 1 11 Maximum total head delivered 1 5m 2 Plumbing 2 1 Inlet 15 mm Push fit inlet manifold 2 2 Outlet BSP to BS2779 3 Electric...

Page 11: ...ra Event XS with wall entry inlet supplies it is recommended that the supply pipework is sealed to the wall to prevent water from leaking back into the wall 1 9 In solid wall installations the supply...

Page 12: ...When using surface mounted inlet supply pipework the use of polyethylene plastic pipe suitable for hot water is recommended to enhance the appearance of the finished installation Internal pipe suppor...

Page 13: ...e B x 20 x 20 D x 20 x 20 15 mm Elbow No of Elbows x 55 No of Elbows x 55 22 mm Elbow No of Elbows x 15 No of Elbows x 15 Add the minimum effective head required 80 Add the minimum effective head requ...

Page 14: ...t recommended because Adrop in cylinder water level could expose a top entry immersion element if fitted Air in water solution gathers at the edge of the cylinder and in the centre during the heating...

Page 15: ...e appropriate configuration for your installation TOP ENTRY SUPPLY CONFIGURATION Falling Water Supply Pipes Falling Electrical Supply in miniature trunking BOTTOM ENTRY SUPPLY CONFIGURATION Rising Wat...

Page 16: ...6 1293809 W2 E Bottom Cable Channel Top Cable Channel Thinned Section of Case Thinned Section of Case Full Case Insert Half Case Insert B Changing the Blanking Plugs WALL ENTRY SUPPLY CONFIGURATION 1...

Page 17: ...17 1293809 W2 E Using this procedure as a guide adjust the steps for bottom entry configurations as appropriate 2 3 1 3 6 5 4...

Page 18: ...ecide on a suitable position for the shower unit and fittings See Installation Plumbing for further details Installation of the Shower Unit 2 3 2 3 1 Hold the assembly against the wall and mark the po...

Page 19: ...l cable to the inlet of the shower unit For rear in let use an elbow fitting We recommend a falling supply to prevent air lock in the pipework 6 For a falling water supply pipe care fully remove the t...

Page 20: ...0 Fixing Points Rubber Feet Chamfer Caution Do not use stainless steel piping for inlet pipework If chrome plated copper pipework is used then all traces of chrome plate must be removed from the conne...

Page 21: ...21 1293809 W2 E 12 11 1 10 Fitting the Cover...

Page 22: ...n and User Guide packed with the fittings Important Align push the temperature control knob onto the temperature hub and ensure it fully clicks into position Fit the insert to lock the knob in place s...

Page 23: ...e to check the function and performance before using the shower for the first time Make sure that all users are familiar with the operation of the shower This guide is the property of the homeowner Tu...

Page 24: ...24 1293809 W2 E 5 6 1 min H H C C 2 3 5 6 7 8 9 Residual water may drain for a few minutes 7 8 Stop Start...

Page 25: ...ct operation of the shower control Warning Resetting the temperature of the temperature stop will also reset the maximum temperature obtainable with the override operated 2 Adjustable Maximum Temperat...

Page 26: ...te This will change the factory setting Turn the temperature spindle until the required maximum water temperature is obtained Caution When resistance is felt DO NOT USE FORCE to turn the spindle any f...

Page 27: ...ot in the thermostatic cartridge 9 Check the maximum temperature setting If necessary repeat the temperature adjustment until the correct the setting is achieved 2 3 5 6 7 8 9 10 11 Stop Start Refer t...

Page 28: ...electable showering temperature to the preset value This setting is recommended for the young the elderly the infirm or anyone inexperienced in the correct operation of the controls 2 3 5 6 7 8 9 Turn...

Page 29: ...29 1293809 W2 E 4...

Page 30: ...reasons this appliance is fitted with an adjustable maximum temperature setting This setting must be checked and adjusted as necessary to suit both site conditions and user s comfort Temperature Contr...

Page 31: ...red water temperature does not exceed 65 C Reset maximum temperature refer to section Commissioning Blend temperature unstable Spray plate blocked Inlet filter blocked Isolating valve partially closed...

Page 32: ...1 metre hot take off dimension Consider increasing cold feed pipe to cylinder to 28 mm diameter Shower runs cool after a short time 1 2 minutes then flow splutters Air ingress into hot pipework Refer...

Page 33: ...hler Mira for further advice Pump speed does not change PCB failure Renew the PCB Low or no water flow Isolating valves closed Inlet filters blocked Check valve fitted incorrectly Appliance sited abov...

Page 34: ...34 1293809 W2 E Front Cover Removal Maintenance 1 2 2 3 1 3 5 6 4 Switch electrical supply Off Turn off the water supply isolation valve...

Page 35: ...et filter meshes Inspect the O seals and renew if required Before refitting the inlet filter cap lightly grease O seals with a silicone based lubricant 4 5 6 Switch electrical supply on Turn the water...

Page 36: ...finishes should be cleaned with a mild washing up detergent or soap solution and then wiped dry using a soft cloth Always read the IMPORTANT SAFETY INFORMATION for your shower Cleaning the showerhead...

Page 37: ...37 1293809 W2 E MOTOR BROWN BROWN ORANGE BLUE THERMAL TRIP POTENTIOMETER SWITCH ON OFF SOLENOID VALVE L N E Wiring Diagram...

Page 38: ...ve Assembly identified D 453 14 Filter Cap Assembly 453 15 Seal Pack identified E 453 23 Mixer Valve Body identified F 453 27 Temperature Override Stop 453 28 Outlet Elbow Assembly identified H 1532 4...

Page 39: ...39 1293809 W2 E Notes...

Page 40: ...Cromwell Road Cheltenham Gloucestershire GL52 5EP 14648 Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase This guarantee only applies in the...

Reviews: