![Kohler Mira Event XS Installation & User Manual Download Page 10](http://html1.mh-extra.com/html/kohler/mira-event-xs/mira-event-xs_installation-and-user-manual_1988975010.webp)
10
1293809-W2-E
1.9. Duty Cycle –
The Mira Event XS Thermostatic pump is continuously rated. The
motor is fitted with a self-resetting thermal trip, designed to operate if motor
temperatures become too high due to abnormally high supply voltages.
1.10.
Noise –
The Mira Event XS is supplied with anti-vibration rubber feet and rubber
wall plugs that isolate the unit from the wall in order to minimize the amount of
noise transmitted. The type of wall the Mira Event XS is fixed to will also affect
the perceived noise level; solid walls will provide a quieter operation.
1.11 Maximum total head delivered –
1.5m
2. Plumbing
2.1.
Inlet –
15 mm Push-fit inlet manifold.
2.2.
Outlet –
½
″
BSP to BS2779.
3. Electrical
3.1.
Appliance power supply –
230–240 V, 50 Hz, fused at 3 Amps, via a double
pole switched fused connection unit (not supplied) with a minimum 3 mm contact
separation in each pole.
3.2.
Power supply connection –
The Mira Event XS is fitted with a terminal block
which will accept cable up to 2.5 mm². Minimum cable size (cross-sectional
area) required under normal installation conditions is 1 mm
2
.
3.3.
Maximum rated power –
150 Watts.
4. Approvals
4.1.
The Mira Event XS complies with UKCA & CE standards.