1. User Maintenance
The Mira Event XS is fully performance tested after assembly. Providing the Mira
Event XS has been correctly installed and is operated as advised, difficulties should
not arise. In the unlikely event that you experience problems with your appliance
then the following procedure will enable you to undertake basic fault finding before
contacting the person responsible for installing your shower.
Malfunction
Cause
Remedy
Maximum showering
temperature too hot.
Maximum temperature
incorrectly set.
Reset maximum
temperature, refer to section:
'Commissioning'
.
Shower temperature too cold.
Hot water cylinder temperature
less than 12°C above shower
temperature.
Maximum temperature
incorrectly set.
Adjust cylinder temperature.
Note!
It is recommended that
the stored water temperature
does not exceed
65°C
.
Reset maximum
temperature, refer to section:
'Commissioning'
.
Blend temperature unstable.
Spray plate blocked.
Inlet filter blocked.
Isolating valve partially closed.
Plumbing system fault.
Clean spray plate. Refer to
the Installation & User guide
supplied with the shower
fittings.
Contact your installer.
Open valve.
Contact your installer.
Pump does not operate.
Electrical supply failure.
PCB failure.
Motor overheated, thermal
switch operated.
Contact your installer.
Contact your installer.
If the thermal switch operates
repeatedly contact customer
services for further advice.
Low or no water flow.
Isolating valves closed.
Inlet filters blocked.
Check valve fitted incorrectly.
Appliance sited above cold
water storage cistern.
Plumbing system fault (airlock).
Open valves.
Contact your installer.
Contact your installer.
The appliance is not suitable
for negative head installations.
Refer to section:
'Installation
Requirements'
.
Contact your installer.
Fault Diagnosis