14
1393517-W2-D
5.
Remove the fixing screw holding on the handle attachment components using a
2.5 mm Allen key. Remove the two attachment components.
Commissioning
Maximum Temperature Setting
Before using the product, the maximum temperature must be checked to make sure
that it is at a safe level. It has been preset to a safe showering temperature under
ideal conditions at the factory, appropriate for most systems. However, site conditions
and personal preference may make it necessary to reset this temperature.
1.
Turn the temperature handle
anticlockwise
until it stops and test that the
temperature of the water from the shower outlet is hot enough.
2.
If not, depress the override button and
carefully
rotate the handle further. If the
water temperature is still not hot enough complete the following procedure.
3.
Rotate the temperature selector handle back to the override position.
4.
Remove temperature handle by pressing the override button and pulling the
handle.
Note: Make sure that the hot water temperature is at least 55°C and that
there is sufficient supply.
Caution! Before testing the mixer, make sure that the hot and cold water
is flowing correctly by exercising the temperature handle from hot to cold.
Warning! Setting the maximum showering temperature to allow for a hotter
bath fill will also enable a hotter maximum temperature to be delivered at
the shower head.
Note: The end
cap on the Assist
handles must be
removed before
pulling off.
Temperature
Handle
Override Button
End Cap