Important
• If the engines are not to be used for 6 months, they must
be protected by carrying out the operations described in
Engine storage (up to 6 months)
(Par. 4.13)
.
• If the engine is still not in use after the first 6 months, it is
necessary to carry out a further operation to extend the
protection period (more than 6 months)
(Par. 4.14)
.
• If the engine is not to be used for an extended period, the
protective treatment procedure must be repeated within 24
months of the previous one.
4.13 Engine storage up to 6 months
Before storing the engine check that:
• The environments are not humid or exposed to bad weather.
Cover the engine with a proper protective sheet against
dampness and atmospheric contaminants.
• The place is not near electric panel.
• Avoid storing the engine in direct contact with the ground.
4.14 Engine storage over 6 months
Follow the steps described in Par. 4.13.
1 -
Engine oil replacement (
2 -
Refuel with fuel additives for long storage.
The following additives are recommended:
DEFA Fluid Plus (Pakelo Lubricants),
Diesel Treatment (Green Star),
Top Diesel (Bardhal),
STP
®
Diesel Fuel Injector Treatment.
3 -
With expansion tank:
make sure that the coolant is up to the
maximum
level.
4 -
Without expansion tank:
Top liquid up until the pipes inside the radiator are covered
by about 5 mm.
Do not overfill the radiator, but leave room for the fuel to
expand.
5 -
Start the engine and keep it idle at minimum speed for 2
minutes.
6 -
Bring the engine to 3/4 of the
maximum
speed for 5÷10
minutes.
7 -
Turn off the engine.
8 -
Completely empty the fuel tank.
9 -
Spray SAE 10W-40 on the exhaust and intake manifolds.
10 -
Seal the exhaust and intake ducts to prevent foreign
bodies from entering.
11 -
When cleaning the engine, if using a pressure washer
or steam cleaning device, avoid directing the nozzle on
electrical components, cable connections and sealed
rings (oil seals etc).
If cleaning engine with a pressure washer or steam
cleaner, it is important to maintain a minimum distance of
at least 200mm between the surface to be washed and the
nozzle - avoiding absolutely electrical components such
as alternators, starter motors and engine control units
(ECU).
12 -
Treat non-painted parts with protective products.
13 -
Loosen the alternator belt
If the engine protection is performed according to the
suggestions indicated no corrosion damage should occur.
4.15 Engine starting after storage
1 -
Remove the protective sheet.
2 -
Use a cloth soaked in degreasing product to remove the
protective treatment from the external parts.
3 -
Inject lubricating oil (no more than 2 cm
3
) into the intake
ducts.
4 -
Adjust the alternator belt tension (
5 -
Refill the tank with fresh fuel.
6 -
Make sure that the oil and the coolant are up to the
maximum
level
.
7 -
Start the engine and keep it idle at minimum speed for a
two about minutes.
8 -
Bring the engine to 75% of
maximum
rated speed for 5 to
10 minutes.
9 -
Stop the engine while the oil is still hot
), discharge the protective oil in a suitable
container.
Warning
• Over time, lubricants and filters lose their properties, so it is
important consider whether they need replacing, also based
on the criteria described in
10 -
Replace the filters (air, oil, fuel) with original spare parts.
11 -
Pour new oil (
) up to the
maximum
level.
12 -
Empty the cooling circuit completely and pour in the new
coolant up to the
maximum
level
UM KDI 1903TCR_2504TCR _ cod. ED0053029490 -
2° ed
_rev.
01
Index
Summary of Contents for KDI-1903TCR
Page 1: ...KDI 1903TCR KDI 2504TCR OWNER MANUAL...
Page 36: ...36 EN NOTES UM KDI 1903TCR_2504TCR _ cod ED0053029490 2 ed_rev 01 Index...
Page 37: ...37 NOTES EN UM KDI 1903TCR_2504TCR _ cod ED0053029490 2 ed_rev 01 Index...
Page 38: ...38 NOTES EN UM KDI 1903TCR_2504TCR _ cod ED0053029490 2 ed_rev 01 Index...
Page 39: ...39 NOTES EN UM KDI 1903TCR_2504TCR _ cod ED0053029490 2 ed_rev 01 Index...