Fuel system
Injection pump for EPA engines
Components
:
1
Holder-delivery valve
2
Locking nut clamp
3
Screw
4
Valve-Spring
5
O Ring
6
Copper gasket
7
Plunger and barrel assembly
8
Pin spring
9
Rack
10
Seat spring
11
Spring tappet
12
Seat phasing
13
Ring snap
14
Tappet assembly roller
15
Pin tappet driver
16
Pump housing
17
Metering sleeve
18
Pin barrel locating
19
Copper gasket
20
Gasket fibre seal
21
Threaded cap
22
Delivery valve assembly
How to check plunger and barrel for internal leakage
This operation is only indicative since pressure changes depending on
the pumping speed.
Connect the delivery union with a 600 bar pressure gauge with safety
valve.
Adjust rack rod at half-stroke.
Turn flywheel according to its direction of rotation so that the plunger
puts the circuit under pressure.
Replace plunger if the displayed pressure is below 300 bar.
Repeat the same operation for the other plunger.
Plunger and Barrel Assembly
1
Barrel
2
Fuel feeding port
3
Control helix
4
Plunger
5
Retardation notch
Plunger diameter is 7.5 mm.
Important
Every plunger matches with its own barrel. For this reason they are not
interchangeable.
Summary of Contents for KD 625/2
Page 1: ...WORKSHOP MANUAL KD 625 2 ...
Page 19: ... 19 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 2 Technical information ...
Page 21: ... 21 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 2 Technical information ...
Page 51: ... 51 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 4 Disassembly Reassembly ...
Page 79: ... 79 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 8 Settings ...
Page 86: ... 86 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 ...
Page 87: ... 87 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 ...