![Kohler KD 625/2 Workshop Manual Download Page 47](http://html.mh-extra.com/html/kohler/kd-625-2/kd-625-2_workshop-manual_1988286047.webp)
- 47 -
KD 625-2 Workshop Manual_cod. ED0053029380_
1° ed
_ rev.
00
4
91
92
90
Disassembly / Reassembly
Valve timing - Angles
The angle values are determined by turning the driving shaft clockwi-
se
S
= Piston at to
p dead centre
I
= Piston at bottom dead centre
α
= Intake valve open
β
= Intake valve closed
γ
= Exhaust valve open
δ
= Exhaust valve closed
Timing angles for checking puposes
(valve clearance = 0,65÷0,70 mm)
α
= 1° before
S
β
= 21° after
I
γ
= 23° before
I
δ
= 1° after
S
HYDRAULIC PUMP
Hydraulic pump p.t.o
A hydraulic pump of group 1 (
1P
) or 2 (
2P
) can be installed on the gear
side, 3rd p.t.o.
Valve timing check
Check valve timing at the crankshaft.
The values shown are checked at the flywheel circumference (with
flywheel of 291 mm. diameter each degree corresponds to 2.5 mm).
Set valve clearance at 0.65÷0.70 mm (after checking restore the value
at 0.15÷0.20 mm).
Set dial gauge on intake valve to a zero value; by rotating the driving
shaft according to its direction of rotation you can measure
α
(intake
valve opening advance referred to top dead centre
S
) and
ß
(intake
valve closing delay referred to bottom (
I
) dead centre).
Follow the same procedure for exhaust valves checking
γ
(exhaust valve
opening advance) and
δ
(exhaust valve closing delay).
Summary of Contents for KD 625/2
Page 1: ...WORKSHOP MANUAL KD 625 2 ...
Page 19: ... 19 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 2 Technical information ...
Page 21: ... 21 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 2 Technical information ...
Page 51: ... 51 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 4 Disassembly Reassembly ...
Page 79: ... 79 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 8 Settings ...
Page 86: ... 86 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 ...
Page 87: ... 87 KD 625 2 Workshop Manual_cod ED0053029380_1 ed_ rev 00 ...