Troubleshooting (cont.)
Solenoid Troubleshooting Table
Symptoms
Probable Causes
Recommended Action
1.
Water leaking
from the valve.
A.
Hose
connections
are not
secure.
A. CAUTION: Risk of
personal injury or
product damage.
Turn
off the main power and
water supply. Check all
connections. Make
adjustments as needed.
B.
Internal leak.
B.
Replace the solenoid
valve assembly.
2.
No audible
″
click
″
when solenoid is
activated.
A.
Loose
solenoid wire
connection.
A.
Check solenoid wire
connection to the circuit
board.
B.
Solenoid
valve is not
functioning.
B.
Replace the solenoid
valve assembly.
Handle Switch Troubleshooting Table
Symptoms
Probable Causes
Recommended Action
1.
Handle LED is lit
when the handle
is closed.
A.
Valve
setscrew
needs
adjustment.
A.
Refer to the
″
Handle
LED Adjustment
″
section.
2.
Handle does not
return to the
upright position.
A.
Valve
setscrew
needs
adjustment.
A.
Refer to the
″
Handle
LED Adjustment
″
section.
3.
Water does not
fully shut off.
A.
Valve
setscrew
needs
adjustment.
A.
Refer to the
″
Handle
LED Adjustment
″
section.
4.
Handle LED does
not illuminate
when the handle
is rotated open.
A.
Loose handle
switch wire
connection.
A.
Check handle switch
wire connection to the
circuit board.
B.
Circuit board
is not
functioning
correctly.
B.
Replace the cover
assembly.
1186051-2-E
18
Kohler Co.
Summary of Contents for K-72218
Page 15: ...Kohler Co 1088977 2 H ...
Page 16: ...1088977 2 H ...
Page 25: ...Installation Installation Instalación Kohler Co 9 1125005 2 B ...
Page 30: ...1125005 2 B Kohler Co ...
Page 31: ...Kohler Co 1125005 2 B ...
Page 32: ...1125005 2 B ...
Page 48: ...1130284 2 E ...
Page 49: ...Installation and Care Guide Electronic Kitchen Faucet K 72218 1186051 2 E ...
Page 108: ...USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com 2013 Kohler Co 1186051 2 E ...