-8-
TROUBLESHOOTING GUIDE
No.
Symptom
1
2
5
6
7
4
8
Probable Cause
Solution
Leaks at quick connect fittings.
No water flow from the water
filtration faucet.
Water flow from the water filtration
faucet becomes small.
All light go out.
Filtered water tastes strange or like
chlorine bleach.
Tubing is not pushed to the backstop.
Tubing is not straight and smooth.
The main water line valve is closed.
The tubing is crimped or sharp
bended.
The filtration cartridge is blocked.
Batteries is exhausted.
Service life of carbon block cartridge
runs out.
Reinsert tubing into push-in fitting as
far as it will go.
Recut tubing.
Check and open it.
Keep the tubing straight.
Replace the cartridge.
Replace the batteries.
Replace the cartridge.
3
Leaks at quick tubing.
Tubing is cracke or scratched.
Simply cut that portion away and
reinsert tubing into push-in fitting.
1
2
5
6
7
4
8
3
·
System tested by Kohler in accordance with NSF / ANSI
Standard 42&53 for the reduction of substances listed
below.
Cyst : Giardia Cysts or Cryptosporidium Oocysts. It is a
common infectious protozoon with diameter of about 0.5-1um.
·
NSF / ANSI
Standard 42&53
0.5-1
PERFORMANCE DATA SHEET
K-5339T-
KT100
K-5339T-
KT100
K-5339T-
KT200
K-5339T-
KT200
K-5339T-
KT400
K-5339T-
KT400
K-5339T-
KT500
K-5339T-
KT500
800
800
0.75
0.75
1000
1000
0.75
0.75
2000
2000
0.75
0.75
3500
3500
0.8
0.8
Model
Particulate
Chlorine/
Taste & odor
/
Lead
Mercury
Cyst*
*
VOC
(volatile organic
compounds)
Capacity (gallon)
(gallon)
Flow rate(gpm)
(gpm)
1211428-T01-A