background image

This document contains important information and details
concerning product installation, operation and maintenance.
Please read it carefully prior to installation and obey all the
instructions during operation.

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or
after the system.
Make certain that installation and connectors must comply
with all state and local plumbing codes.
Installation and maintenance must be done by qualified
plumbing professionals designated by dealers authorized
by Kohler.
For cold water use only (Temperature Range: 1-38 C);
This filter must be protected from freezing, which can
cause cracking of the filter and water leakage. Drain filter
when room temperature drops below 1 C.
Pressure Range: 100-400 kPa, If water pressure exceeds
400kPa, please install pressure limiting valve. Otherwise,
the ultrafiltration membrane may not achieve best filtration
effect due to long time overpressure. (Please consult
plumbing professionals or dealers authorized by Kohler
for water pressure measurement).
Do not install where water hammer conditions may occur.
If water hammer conditions exist you must install a water
hammer arrester.
Do not install in direct sunlight

outdoors or where

blowtorch or other high temperature sources are nearby.
The filter must be installed with the inlet, outlet and self-
cleaning ports as labeled. Make sure not to reverse
connections.
Before your installation make sure cold water valve is
turned off under the sink.
Water filtration faucet is not supplied with the product. you
will need to purchase a water filtration faucet with a G1/2"
connector.

·

·

·

·

·

·

·

·

·

·

°

°

SKU K-5339T-KTXXX are shown as KTXXX.

Main parts included:

Other parts included:

Filter base
Filter cartridge Level 1
Filter cartridge Level 2
Water tray

3/8" x1/2" Male Thread Faucet Adapter
----( One for each of KT100

KT200

KT400)

----( Two for KT500)
Water supply adapter
----(K-5339T-KT500 not included)
3/8" x 1/2" Female Thread Adapter
----(only K-5339T-KT500 included)
AA alkaline dry batteries
----(3 batteries)
3/8" Plastic tubing
----(KT100

KT200

KT400: Black

Blue)

----(KT500: Black

Yellow

Blue)

Pipe clip

·

·

·

·

·

·

·

·

·

·

(

1-38

)

1

100-400

400

(

)

(

)

G1/2

K-5339T-KTXXX KTXXX

3

4

----(KT100

KT200

KT400

1

)

----( KT500:2

)

(1

)

----(K-5339T-KT500

)

3

4

----(

K-5339T-KT500)

AA
----(3

)

3
----(KT100

KT200

KT400

)

----(KT500

)

-1-

BEFORE YOU BEGIN

GETTING STARTED

, 2014

Copyright Kohler China Ltd., 2014

1211428-T01-A

Summary of Contents for K-5339T-KT100

Page 1: ...Cuff Water Filtration System K 5339T KT100 K 5339T KT200 K 5339T KT400 K 5339T KT500 158 200436 1211428 T01 A ...

Page 2: ...ement Do not install where water hammer conditions may occur If water hammer conditions exist you must install a water hammer arrester Do not install in direct sunlight outdoors or where blowtorch or other high temperature sources are nearby The filter must be installed with the inlet outlet and self cleaning ports as labeled Make sure not to reverse connections Before your installation make sure ...

Page 3: ...se if necessary Adjustable wrench Utility knife or tube cutter Thread Sealant Tape Adapter 2 Kohler reserves the right to change marked dimensions without prior notice 2 3 1 4 5 8 6 9 7 10 Unit mm Reference Value ROUGHING IN 431 310 133 1211428 T01 A ...

Page 4: ...supply adapter female threaded stub to the cold water supply valve male threads as shown Hand it tighten and snug with wrench Screw the female threaded tap faucet stub to the water supply adapter 4 B KT500 Screw the 3 8 x 1 2 Female Thread Adapter threaded stub to the cold water supply valve male threads Hand it tighten and snug with wrench then Screw 3 8 x 1 2 Male Thread Faucet Adapter to the fe...

Page 5: ...Black 3 3 8 Plastic Tubing Black 3 3 8 Plastic Tubing Yellow 3 Hot Water Supply Valve Water Filtration Faucet Water Filtration Faucet 3 8 x 1 2 Male Thread Faucet Adapter 3 4 3 8 x 1 2 Male Thread Faucet Adapter 3 4 Water Supply Adapter 3 8 x 1 2 Female Thread Adapter 3 4 Hot Water Supply Valve Note Note Cut tubing straight with a utility knife make sure there are no cuts nicks flat spots or sharp...

Page 6: ...of the cartridge were aligned the color filled icon on the filter base it will be fully installed Figure 8 Step 4 Test System NOTE Turn on the water filtration faucet Slowly turn on the cold water supply valve Run water to flush trapped air It is normal for there to be Residual air in the System causing bubbles temporary cloudiness in the water Turn off the water filtration faucet Keep the cold wa...

Page 7: ...ure 9 Step 7 Display Confirmation Push and hold the reset button for approximately 5 seconds until all lights are on Repeat this action each time after filtration replacement So the reminder of filtration replacement could be reset Figure 10 9 10 Figure 9 9 Figure 10 10 Warning Button Battery Life Light Reset Button Filter Service Life Light 1211428 T01 A ...

Page 8: ...ter Model Cartridge Model K 5339T KT100 K 5339T KT200 K 5339T KT400 K 5339T KT500 1208778 1208811 1208812 1208779 1208813 1208814 1208781 1208817 1208818 1208782 1208819 1208820 After replacing the filter cartridge in order to avoid residual water storage in kitchen cabinets small amount of water residual will be run into the water tray Empty the water tray and put it back Please timely empty the ...

Page 9: ...e tubing straight Replace the cartridge Replace the batteries Replace the cartridge 3 Leaks at quick tubing Tubing is cracke or scratched Simply cut that portion away and reinsert tubing into push in fitting 1 2 5 6 7 4 8 3 System tested by Kohler in accordance with NSF ANSI Standard 42 53 for the reduction of substances listed below Cyst Giardia Cysts or Cryptosporidium Oocysts It is a common inf...

Page 10: ... 9 K 5339T KT100 0 1 0 4MPa 1L min 1000L 2001 19 2014 0080 K 5339T KT200 1L min 2014 0080 K 5339T KT400 1L min 2000L 2013 0335 K 5339T KT500 2L min 2013 0336 1211428 T01 A ...