15. Complete the Installation
NOTE:
Do not caulk the access cover to the floor.
If this installation uses wall mounted electrical or water supplies, cut a recess in the access cover
using a utility knife at the spot marked on the access cover.
Place the access cover over the opening in the back of the toilet.
Caulk around the base of toilet. Do not caulk the area where the access cover meets the floor.
16. Troubleshooting
This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale
distributor.
Symptoms
Probable Causes
Recommended Action
1.
The toilet does not flush.
A.
Various.
A.
Perform the troubleshooting steps
below.
2.
The toilet randomly
flushes 2 times.
A.
The tank is overfilling.
A. Immediately
turn the water off (the
water will need to be turned back
on prior to troubleshooting) OR
perform the troubleshooting steps
below.
To troubleshoot this toilet you must first:
Unplug the toilet or turn off the power.
If needed, turn on the water supply.
Plug the toilet back in or turn the power back on.
IMPORTANT!
When the power is turned on, the toilet may flush three times and then function correctly.
No action is needed if this happens.
Note the results (how many times the toilet flushes, whether it operates normally).
Consult the following table and perform the recommended action.
Access Cover
Toilet Back
Access
Opening
Cut with
utility knife.
Do not caulk base of
access cover.
Caulk
base of
toilet.
1035530-2-C
14
Kohler Co.
Summary of Contents for K-3492
Page 46: ...1035530 2 C...