Troubleshooting (cont.)
Symptoms
Probable Causes
Recommended Action
1.
The toilet flushes 3 times,
then operates normally.
A.
The fill valve is not turning off.
A.
Repair or replace the fill valve.
B.
The motorized valve is not
closing.
B.
Repair or replace the motorized
valve.
2.
The toilet flushes 5 times.
A.
The level switch has an
intermittent connection.
A.
Repair or replace the level switch.
B.
The level switch is stuck in the
up position.
B.
Repair or replace the level switch.
C.
The level switch is not properly
connected.
C.
Reconnect the level switch
properly.
D.
The level switch does not move
freely.
D.
Replace the level switch.
3.
The toilet fails to operate.
A.
There is a problem with the
wiring.
A.
Check the wiring and connect the
power.
B.
The GFCI or ELCB is tripped.
B.
Reset the GFCI or ELCB (if
applicable).
C.
There is a problem with the
pump connection.
C.
Check the pump connection.
D.
The actuation switch is not
properly connected.
D.
Check the actuation switch
connection.
E.
The level switch is not properly
connected.
E.
Check the level switch connection.
F.
The pump assembly does not
work.
F.
Replace the pump assembly.
G.
The actuation assembly does not
work.
G.
Replace the actuation assembly.
Kohler Co.
15
1035530-2-C
Summary of Contents for K-3492
Page 46: ...1035530 2 C...
Page 47: ...1035530 2 C...