INSTALLATION
Install Bushing
Installation Site
≥75
≥90
≥90
≥90
≥50
≥50
≈28
≈130
≈130
1.
Determine the installation location per rough-in
dimensions. Chisel out a slot and install the supply
tubing. Turn off the water supply. The depth of the
slot is no less than 80mm, see the figure below
for rough-in dimension requirement.
While installing 8787X-B03, chisel out the slot
indicated in the dot line area of figure below for
installation of bushing.
NOTE :
a. No light shall enter or be reflected into the sensing
window.
b. No reflectible objects in front of the sensing
window (e.g., mirror, polishing stainless steel and
some other polished plate).
c. No strong ultraviolet radiation or electromagnetic
field nearby.
2.
Put the flush valve into the slot. Then connect
the water supply and make the outlet aligned with
the center of the urinal stall. Secure the flush valve
with supporting block to make it flat and straight.
Then connect the inlet pipe.
According to the dimensions of the urinal stall, the
outlet fitting are connected and installed as shown
in the rough-in (see P.3)
NOTE :
It is recommended that a temporary rubber or
plastic hose is attached to the inlet pipe, and the
water supply line should be flushed clean of dirt and
debris.
Connector
Water Supply
(Recommended Inner Diameter Is More Than 25mm)
Nut
Outlet Connection
Outer diameter
of Bushing ≤25mm
Battens
SENSOR SPECIFICATIONS
Model
8787X-B03 (AC)
Power
220V AC 50/60Hz
Liter per flushing
Water pressure at 0.18~0.55 MPa : average flushing is no more than 3.8L
Water pressure at 0.1 MPa : no more than 3L
Temperature
Environmental temperature : 1 to 55°C
Starting pressure
0.05~0.86 MPa
Sensing distance
70 cm away from sensing window (Automatic adjustment range : 50~70cm)
Testing time
About 2 seconds or 5 seconds (Automatic adjustment)
Flushing Mode
Dual flushing
1106445-X2-A
4