2. Install the Yoke
NOTE:
The yoke has two-sided pipe adapters that can be reversed
for use with either 1/2” pipe or copper tubing.
Connect the water supply lines to the supply yoke so the
installed water supplies will be between 2
″
(2.5 cm) and 3-1/2”
(8.9 cm) from the finished wall.
3. Install the Valve - Ceiling Installations
IMPORTANT!
Perform these steps for ceiling installations only.
Remove the aspirator, plaster guards, and valve units from the
yoke.
Turn the yoke upside down.
Install the aspirator into the bath outlet of the yoke.
Reinstall the valve units, being sure to install the gray-stemmed
valve on the right side. The
″
D
″
on the valve must point
downward.
Reinstall the plaster guards.
Finished
Wall
Adapter
2" (5.1 cm) Min
3-1/2"
(8.9 cm) Max
1/2"
Piping
Valve Stem
Aspirator
Off Position
Yoke
Plaster
Guard
Bath
Outlet
113725-2-AB
4
Kohler Co.
Summary of Contents for K-11608