background image

11

115982-2-

BA

 (-)

Kohler Co., Kohler, WI

B.  PUMP BANDING STRAP CUT

NOTICE: This step is necessary to make your
Kohler whirlpool operate more quietly.

1.

Use tin snips to cut the two banding straps. These
banding straps secure the pump to the
whirlpool-mounted shipping bracket. When the
banding straps are cut, the pump base and pump
will drop about 1/2” until they rest on the subfloor. If
the pump drops more than 1/2”, be sure the proper
pitch is maintained (with shims under the motor) to
allow the pump to drain through the suction line
when the whirlpool is drained.

Shipping Bracket
(leave attached
to bath)

Suction Line

Pump

Subfloor

Banding Straps

Pump Base

2.

If the subfloor is level, no adjustments to the pump
are necessary. Proceed to Step 3. If the subfloor is
not level, slide plywood shims between the pump
base and the subfloor, but only high enough to allow
water to drain out the suction line when the bath is
drained.

NOTE: Do not raise the pump higher than it was before
you cut the banding straps. If the pump is raised too high,
it may not prime properly.

Shim if necessary, using 5” x 7”
(minimum) plywood

Drainage

Suction Pipe

3.

To minimize bath noise and vibration, be sure the
pump is not in direct contact with the shipping
bracket after the banding straps are cut. The pump
base contains rubber isolation feet to reduce pump
noise and vibration.

Pump

Rubber
Isolation
Feet

C. INSTALL PLUMBING

CAUTION: Risk of damage to bath bottom and
subfloor.
 Ensure a watertight seal on the bath
drain connections.

1.

When the bath is securely positioned, connect the
drain to the trap.

NOTE:  An access panel will simplify future mainte-
nance.

Connect Here

2.

Open hot and cold valves and check all supply
connections for leaks.

3.

Run water into the bath, and check the drain
connections for leaks.

Summary of Contents for Freewill K-12105-H

Page 1: ...Freewill Barrier Free Bath Whirlpools K 12105 H K 12106 H 115982 2 BA 1999 Kohler Co...

Page 2: ...her electrical equipment and exposed metal in the vicinity as needed to comply with local requirements DANGER RISK OF INJURY Hot whirlpool baths can put certain stresses on the body as do any hot bath...

Page 3: ...Information 120 V 60 Hz 12 WATER TEST WHIRLPOOL ELECTRONICS 12 COMPLETE FINISH WALL 13 COMPLETE INSTALLATION 13 Install Whirlpool Trim Kit 13 Install Faucet And Drain Trim 13 Install Grab Bars 13 Inst...

Page 4: ...n Outlet 2 1 4 D Approximate measurements for comparison only Pump high HP low HP V Hz A 2 speed 1 1 8 120 60 16 5 D INSTALLATION NOTES Read the entire installation instruction before beginning the in...

Page 5: ...on 3 PRODUCT REQUIREMENTS A SUMMARY OF KEY REQUIREMENTS Install unit to a level subfloor Provide properly dimensioned framing Recess installation is recommended B PLUMBING SPECIFICATIONS Confirm adequ...

Page 6: ...our new acrylic module is too large to fit through a standard door opening The unit must be placed within the installation area prior to completion of framing An optional procedure is to omit studs in...

Page 7: ...vide this clear floor space with either a front or side user access 2 Consider the path of the wheelchair user when building the clear floor space Be sure there is sufficient room for a wheelchair use...

Page 8: ...truction multiple unit installations At least one unit should have access through which the other unit may be accessed 4 In masonry or fire rated partitions Provide access to plumbing connections 5 Un...

Page 9: ...plate around the recess opening 2 If extra grab bars are specified Provide 2x6 bridging or attachment at specified positions Refer to the grab bar manufacturer s instructions NOTE A 5 diameter opening...

Page 10: ...the unit 3 Use a hole saw to drill the holes required Drill from the finished face of the unit CAUTION Risk of product damage When moving the unit do not flex or damage may occur 4 Clean the bath rece...

Page 11: ...etween the pump base and the subfloor but only high enough to allow water to drain out the suction line when the bath is drained NOTE Do not raise the pump higher than it was before you cut the bandin...

Page 12: ...ol has been completed at the factory A licensed electrician must install a GFCI protected 120 V 20 A grounded outlet Your whirlpool may then be plugged into this outlet No other load should be on this...

Page 13: ...sistant Wall Material 11 COMPLETE INSTALLATION A INSTALL WHIRLPOOL TRIM KIT Refer to the installation instructions packed with the trim kit when installing the jet or suction trim B INSTALL FAUCET AND...

Page 14: ...12 CLEAN UP AFTER INSTALLATION When cleaning up after installation do not use abrasive cleansers as they may scratch and dull the bath surface Use warm water and a liquid detergent to clean the surfa...

Page 15: ...ng counterclockwise To reduce air and water rotate it clockwise Shut off whirlpool Restart whirlpool after 20 minute cycle is complete Up More Down Less 14 TROUBLESHOOTING PROCEDURES A FLEXJET INSTALL...

Page 16: ...kit installed incorrectly B Reinstall trim kit checking for damage to O ring 3 Whirlpool stops automatically A GFCI trips A Identify source of fault and correct automatically before 18 minutes B Suct...