Safety Information
¨
Products manufactured by Englefield are safe provided they are installed,
used and maintained in good working order in accordance with our
instructions and recommendations. Always refer to this manual if you have
any doubt.
¨
The appliance must be earthed. Improper grounding could cause electrical
shock. The earth continuity conductor of the electrical installation must be
effectively connected to all exposed metal parts of other appliances and
services in the room, which in the heater is to be installed to conform to local
regulations and ensure proper earthing/grounding for ELCB to be effective.
¨
If any of the following conditions occur, immediately switch off the mains
and contact the Call Center. Never attempt to repair the unit by yourself:
• If the heater begins to make an odd noise, smell or smoke.
• If ELCB trips and power indicator does not light up.
• Water temperature cannot be controlled.
• If the heater shows signs of a distinct change in performance.
• If water leaks from inside.
¨
When the shower is used by someone such as child, elderly person, sick
person and physically handicapped person, the person concerned is kindly
requested to pay attention and check the shower temperature by hand from
time to time. User is advised to test and adjust the water temperature before
using.
¨
During lightning/thunder, switch off the electric supply to the shower unit
in advance to protect the shower unit against possible damage.
¨
Installation must be carried out by a qualified personnel and in compliance
local authority regulations.
¨
This heater must be permanently connected to the direct main line supply.
A plug and a socket are not recommended to use.
¨
For the correct size of wire conductor corresponding to different electrical
loadings, please refer to cable size table on page 12.
¨
The heater will not function if there is insufficient water flow (min 2.0 litre/
min) to trigger the flow switch.
¨
The built-in ELCB will automatically cut off the power supply in case there is
a current leakage over 15 mA.
¨
The thermostat will automatically cut off the power supply if it has sensed
an abnormal rise in water temperature.
¨
For the spray head must be descaled regularly.
NOTE:
When removing the unit from package, a small amount of water may be
found inside. This is normal as the unit is tested during manufacturing process.
Kohler Co.
3
1237889-X2-G
Summary of Contents for Englefield K-5627X
Page 34: ...1237889 X2 G 34 Kohler Co ...
Page 35: ...Kohler Co 35 1237889 X2 G ...