INSTALL SLIP-FIT SPOUT – ALL MODELS

NOTE: To improve clarity, only the diverter spout used for
the K-1096 model is shown. Installation of both diverter
and non-diverter spouts is identical.

CAUTION: Risk of internal seal damage.
Loosen spout setscrew with a 5/32” hex wrench
prior to installing the spout.
CAUTION: Risk of internal seal damage. Do not
use petroleum-based lubricants. If spout will not
slide over tubing, use soapy water or a
silicone-based lubricant.

Cut the tubing so it extends between 1-1/2” and 2-7/8”
beyond the finish wall. Loosen spout setscrew with 5/32”
hex wrench. Slide the spout over the 1/2” copper tube,
and carefully retighten the setscrew.

Flush hot and cold water through the spout for one minute.

Fig. #12

1-1/2” to 2-7/8”

1/2” Copper Tube

Slip-Fit Spout

Setscrew

INSTALL N.P.T. SPOUT – ALL MODELS

NOTE: To improve clarity, only the diverter spout used for
the K-1096 model is shown. Installation of both diverter
and non-diverter spouts is identical.

Remove the temporary nipple from the bath ell. Apply
thread sealant to the threads of a 1/2” nipple. Install the
nipple to the bath ell so it extends 3-7/8” beyond the finish
wall. Carefully thread the spout to the nipple with a clean
strap wrench.

Flush hot and cold water through the spout for one minute.

Fig. #13

3-7/8”

Nipple

N.P.T. Spout

INSTALL SHOWER ARM AND
SHOWERHEAD – ALL MODELS

CAUTION: Risk of product damage. To avoid
plugging the showerhead spray outlets, use thread
sealant tape on shower arm threads.  Do not use
thread sealant (pipe dope).

Remove the temporary nipple from the shower ell.

Apply a bead of plumbers putty or other sealant around
the wall flange according to the manufacturer’s
instructions. Slide the wall flange onto the shower arm.
Apply thread sealant tape to the shower arm threads.
Thread the shower arm into the shower ell. Tighten with
a clean strap wrench.

Slide the wall flange against the wall, and tighten the set-
screw. Remove any excess sealant.

Flush hot and cold water through the shower arm for one
minute.

Install the showerhead to the shower arm using thread
sealant tape. Tighten with a clean strap wrench.

Fig. #14

Shower Ell

Wall Flange

Plumbers Putty

Setscrew

Showerhead

Shower Arm

Summary of Contents for CORALAIS BODYSPA K-1096

Page 1: ...ower Pay special attention to this feature when planning your site preparation Avoid excessive heat if you solder connections to prevent damage to the fitting Flush all piping thoroughly before installing the valve Observe all local plumbing codes Do not force the handle s in any direction To turn the valve off gently turn to the Off position For the K 1097 do not use any plastic pipe between the ...

Page 2: ... valve when such changes occur Pressure balanced valves may not provide protection against scalding if there is a failure of other temperature limiting devices elsewhere in the plumbing system The installer is responsible for installing the valve and adjusting the maximum water temperature of this pressure balanced valve according to instructions This valve meets or exceeds ANSI A112 18 1M and ASS...

Page 3: ... IMPORTANT Secure the bath and shower piping to the support framing Proceed to Fig 3 Fig 1 10 4 72 78 TO FLOOR TYPICAL SUPPORT FRAMING K 1097 MODEL ONLY Determine the installation location of both valves the showerhead and the spout Install the support framing as required IMPORTANT Secure the bath and shower piping to the support framing Proceed to Fig 4 Fig 2 10 4 72 78 TO FLOOR TYPICAL 48 TO FLO...

Page 4: ...he K 1098 reinstall the aspirator at the top of the yoke Do not overtighten For the K 1097 discard the aspirator Reinstall the valve units with the colored dot valve on the left side right side for ceiling supplies Reinstall the plaster guards For K 1096 model proceed to Fig 6 For K 1097 model proceed to Fig 7 Fig 5 Ceiling Supplies Aspirator Hot Cold D shape Down D shape Up INSTALL 2 HANDLE YOKE ...

Page 5: ... 2 Copper or Pipe 1 2 Adapter or Solder Direct Hot Side Shower Outlet 1 2 Pipe Cap INSTALL SINGLE CONTROL VALVE K 1097 MODEL CAUTION Risk of product damage The shower valve contains plastic components Do not apply excessive heat if you solder the valve connections NOTE If the valve is to be installed in a two valve back to back configuration proceed to Back to Back Installation procedures on Page ...

Page 6: ... out for thick wall installation Install the plaster guard and mud guard over the cap assembly and secure them to the valve body with screws NOTE The finish wall must line up within the front to back depth of the installed plaster guard The plaster guard may be removed after the wall is completed Remove and discard the mud guard Thin Wall Installation Cut a 4 diameter hole in the wall material Ide...

Page 7: ...he temporary nipple from the bath ell Apply thread sealant to the threads of a 1 2 nipple Install the nipple to the bath ell so it extends 3 7 8 beyond the finish wall Carefully thread the spout to the nipple with a clean strap wrench Flush hot and cold water through the spout for one minute Fig 13 3 7 8 Nipple N P T Spout INSTALL SHOWER ARM AND SHOWERHEAD ALL MODELS CAUTION Risk of product damage...

Page 8: ... counterclockwise to shut the water off Reinstall the handle and face plate O Ring Upper Limit Stop Tab Valve Stem Lower Limit Stop Groove Fig 16 7 INSTALL VALVE TRIM INSTALL ESCUTCHEONS TO 2 HANDLE YOKE ALL MODELS Apply a bead of plumbers putty or other sealant to the escutcheon according to the putty manufacturer s instructions Install the escutcheons over the threaded sleeves and align on the w...