background image

Module Bathing System:

(Models With and Without Whirlpool)

Owner’s Manual

114825-5-

AA

 (A)

1998 Kohler Co.

Summary of Contents for BodySpa

Page 1: ...Module Bathing System Models With and Without Whirlpool Owner s Manual 114825 5 AA A 1998 Kohler Co ...

Page 2: ... guard on the suction fitting Never drop or insert any object into any opening Use this unit only for its intended use as indicated in this manual DO NOT use attachments not recommended by the Kohler Co Keep small objects such as bath toys and bathing accessories out of the BodySpa while the pump is operating NOTE The BodySpa and whirlpool action can cause even a small amount of bubble bath bath s...

Page 3: ...eaning Your BodySpa Module 9 Cleaning Your Removable Seat 9 Flushing Your BodySpa System 9 Flushing Your Whirlpool System 9 Cleaning Your BodySpa Door Enclosure 10 IMPORTANT CONSUMER INFORMATION 10 Requesting Service 10 Limited One Year Warranty 10 TROUBLESHOOT THE BODYSPA SYSTEM 11 TROUBLESHOOT THE WHIRLPOOL SYSTEM 12 1 INTRODUCTION All information in this manual is based upon the latest product ...

Page 4: ...ed inside the module for quick access You can vary the intensity of your hydro massage experience from gentle to vigorous with the touch of a finger B BODYSPA BASICS Your BodySpa needs less than 30 gallons of water to operate because it recirculates the tempered water you put in the bath basin Approximately 45 gallons of water is needed to operate the whirlpool The BodySpa and whirlpool systems re...

Page 5: ...orth to focus your hydro massage exactly where you want while remaining seated WARNING Risk of personal injury Do not attempt to stand on the removable seat C THE BODY JETS There are six Body Jets integral to the module side wall They are positioned at an angle to allow you to move in and out of the water spray to concentrate your hydro massage where you want The Body Jets are arranged in horizont...

Page 6: ... USE YOUR BODYSPA WARNING Risk of injury or property damage BodySpa controls are factory installed Do not relocate or modify controls as this could adversely affect safe operation Please read and follow these steps carefully so you can safely enjoy the benefits of BodySpa hydro massage bathing Remove your eyeglasses contact lenses and loose jewelry before entering the BodySpa module Shower before ...

Page 7: ...re to exceed 104 F 2 Turn on the BodySpa by pressing the On Off button on the control switch mounted on the module door column Water will flow from the six Body Jets atlow speed 3 Use the and arrows to increase or decrease the water force 4 Press the On Off button a second time to turn off the BodySpa 5 A built in timer automatically turns off the BodySpa after 20 minutes of continuous operation N...

Page 8: ...hut off whirlpool Restart whirlpool after 20 minute cycle is complete Up More Down Less To add air and water to whirlpool action rotate the trim ringflange counterclockwise To reduce air and water rotate it clockwise D HELPFUL TIPS TO INCREASE ENJOYMENT OF YOUR BODYSPA If you choose to use your BodySpa for more than one 20 minute cycle we suggest you open the door for a moment between cycles This ...

Page 9: ...ing a soft cloth and warm water Stubborn dirt or stains may require a non abrasive cleanser Do not use abrasive cleansers or solvents on the removable seat C FLUSHING YOUR BODYSPA SYSTEM Flush your BodySpa system twice a month or more depending upon usage Use the following sequence Fill the bath with hot water to a level 2 above the suction cover Add 2 teaspoons of a low foaming dishwasher deterge...

Page 10: ...r Service Department 444 Highland Drive Kohler WI 53044 U S A 4 Include all pertinent information regarding your claim including a complete description of the product model numbers colors finishes and the date the product was installed Include adescription of the problem and a photocopy of your invoice for the products involved Also give us the name of the contractor and distributor B LIMITED ONE ...

Page 11: ...Jet is blocked A Remove blockage Refer to dealer installer 4 Water flow increases when keypad button is A Variable flow valve wiring error A Reverse variable flow valve wire connections Refer to dealer installer keypad button is pressed or decreases when keypad is pressed B Labeled end of control switch cable plugged into control box B Reverse cable so labeled end is plugged into control switch Re...

Page 12: ...tops automatically before 18 minutes A GFCI ELCB trips A Identify source of fault and correct If problem persists Refer to installer dealer B Suction blocked B Remove obstruction C Jets are blocked C Remove blockage refer to installer dealer D Motor overheated and protection device activated D Check for blockage at motor vents Remove blockage and allow motor to cool Check for suction blockage Remo...

Reviews: