background image

请在通电

10

分钟后开始使用该系统。

因为此段时间设定为调节感应范围得待机状态。此时系
统不工作。

接上电源约十分钟为自动调节距离状态,此过程中系统
无冲水动作。在接通电源之前,务必清理感应冲洗器窗
口前得杂物,保证感应窗口前无任何物体,以免影响自
动调距。

约十分钟后感应器开始正常工作,如发现冲水量过小,
可参考

冲洗时间设定

进行改变冲洗时间,从而改变冲

水量大小。

(

仅适用于

K-4915T

K-4915T-C05)

在接通电源之前,务必清理感应冲洗器窗口前得杂物,
以免影响自动调距。

电池的更换

(仅适用于直流型)

电池耗尽时,电池指示灯将每隔2秒闪烁一次,感应器停止
工作,直至更换电池。更换时打开电池盒盖,换上新电池即
可。

    

注意:

更换时注意电池极性。新旧电池不可混用。

过滤装置的清洗

初装一段时间或长期使用后,发现出水量明显变小,可清
洗阀体中的过滤装置。

旋下螺母,取出滤网,清洗后重新装入即可。

 注意:

清洗前,请先关闭止水阀。

Don’t  use this system after 10 minutes power on.

The induction distance will be adjusted and this system will 

not work during this time.

The state of distance adjustment has been last about 10 

minutes after power on. No flushing druing this period. 

Before power on, clear the unwantedobjects in front of the 

sensor window to shortening the sensing distance.

The sensor will begin to work normally after 10 minutes. If 

flushing water volume is not enough, reset the flushing time 

referring to “Flushing Duration Setting” in order to changing 

the flushing water volume. (Only for K-4915T or K-4915T-

C05)

Before power on, clear the unwantedobjects in front of the 

sensor window to shortening the sensing distance.

When the batteries are nearly exhausted, the indicator will flush every 2 

seconds, the sensor stop working until new batteries are changed.

When changing the batteries, open the cover of battery box and insert 

new batteries.

       NOTE: 

Pay attention to the pole of batteries and do not use new and 

old batteries at the same time.

If the flushing volume is reduces,the filter assy must be cleaned.

Remove  the nut and take out the filter assy. clean it with a brush 

and reinstall.

        

NOTE: 

Turn off the Stop valve before cleaning.

WORKING STATUS FLUSHING

工作状态

REPLACEING BATTERIES

(Only for DC)

CLEAN THE FILTER ASSY

Screws

螺钉

Batteries

电池

Cover of Battery box

电池盒盖

 Battery box

电池盖

Valve Assy

阀体组件

Nut

螺母

Filter Assy

滤网组件

Stop Valve

止水阀

8

1146969-T01-

K

Summary of Contents for BARDON VITREOUS CHINA TOUCHLESS K-4915T

Page 1: ...eave instructions for the consumer BEFORE YOU BEGIN A HOW TO USE THESE INSTRUCTIONS A B NOTES Observe all local plumbing and building codes Stop Valve has a 1 2 NPT inlet supply connection Fixture dim...

Page 2: ...g is no less than 10mm otherwise the flushing will be affected 1 2 N P S INLET FOR STOP VALVE 362mm 146 20mm 20mm 152mm 2 N P S TAP OUTLET DETAILS 2 N P S TAP OUTLET DETAILS 1 2 N P S INLET FOR STOP V...

Page 3: ...p valve assembly and tighten connection NOTE Stop valve should face left side of tank when tighten Please clean the inside of water supply pipe before connect ing to the product Plug seal ring into in...

Page 4: ...and the pipes into the tank of urinal Adjust the distance of outlet pipe and plastic pipe Then make the outlet pipe aim at the sealing washer and make the valve assy aim at the outlet of stop valve Pl...

Page 5: ...as below CAUTION a Do not connect 220V AC Power supply to DC wiring terminal b Do not damage the covering of AC power unit or remove screws to avoid leakage K 4915T K 4915T W K 4915T Y 3 K 4915T C05...

Page 6: ...of battery box Tighten the screw otherwise the batteries may be affected with damp Notice a Keep the connector away from water b Don t mistake the direction of inlet and outlet c Do not connect the D...

Page 7: ...the hooks facing opposite the direction illustrated Using a 5 8 wrench assemble and tighen nut washer and lock nut on both sides of urinal CAUTION Risk of chipping or breaking urinal Do not overtighen...

Page 8: ...15T C05 Before power on clear the unwantedobjects in front of the sensor window to shortening the sensing distance When the batteries are nearly exhausted the indicator will flush every 2 seconds the...

Page 9: ...sher disinfect or other deodorizing cleaning solvent directly into the sensor c Keep wire away from water d Don t attack the sensor window 1 8 30 30 Approach the supplied special magnetic stick flushi...

Page 10: ...ng Water Volume Deodorization Flushing Starting Pressure Operation Temperature Ambient water temperature of 1 55 One forced flushing will be conducted if the urinal is being used continuously for 2 mi...

Page 11: ...rn off stop valve flush to clean off water supply line 1 2 3 4 1 2 3 4 1 2 3 4 1 10 2 3 4 1 Urinal is designed or use with potable water Avoid water that includes a lot of contaminants or with acid al...

Page 12: ...VICE PARTS PAGE VITREOUS CHINA TOUCHLESS TM URINAL 1066275 SP 1111671 SP 1128222 SP 1128223 SP 1146974 SP 1146975 SP 1066277 SP 1111672 SP 1148065 SP 16306T NA K 4915T K 4915T W K 4915T WC05 K 4915T C...

Reviews: